Drum Cartridge

Xerox WorkCentre Pro 412 User Guide
The Drum Cartridge requires replacement when the Drum life
warning is displayed, after approximately 15,000 copies.
If you are experiencing streaks or spots on your prints there is
an option for cleaning the drum.
CAUTION: Do not expose the green drum to light for an
extended period. Never expose the drum to direct
sunlight or touch the drum surface. Damage or poor
image quality may result.

Cleaning the OPC Drum

If you are getting streaks or spots on your print, you may set
the product to clean the drum cartridge.
½
Ensure that paper is loaded.
½
Press [Menu/Exit] on the control panel to enter menu mode.
½
Press
or
until 'MAINTENANCE' appears, then
press [Select].
½
Press [Select] to access 'CLEAN DRUM'.
The LCD displays 'CLEANING DRUM PLEASE WAIT...'
The machine automatically pulls in a sheet of paper, and
prints it out. The toner particles on the OPC drum surface are
fixed to the paper.