250 ms/s dual channel digital storage oscilloscope
Table of Contents

Advertisement

4-52E
'savee.ar
If pushbutton CLEAR is pushed and dots are selected for display, a
zero line is written into the accumulator (RO) and no traces are
displayed on the screen.
If DOTS is off or SMOOTH is selected for display and pushbutton
CLEAR is pushed,
a zero line is written into the accumulator (RO) and
displayed on the C.R.T. screen.
The cleared contents of the accumulator can be saved in one of the
other registers R1..R3, to clear the contents of these registers.
When
pushbutton
CLEAR
is pushed during a SINGLE-shot,
a
MULTIPLE-shot or a ROLL-mode operation, the CLEAR pushbutton
has a RESET function.
The function CLEAR
is not possible in the LOCK
mode.
If pushbutton SAVE/PLOT
is pushed, the SAVE/PLOT
menu
is
displayed. See 4.2.9.1.