6.1.10
6.1.11
6.2
6.2.1
6.2.2
6.2.3
6.2.4
CHARACTERISTIC
SPECIFICATION
Focus
Manuaily set
Trace rotation
-Minimum
range
14°
SIGNAL ACQUISITION
Sampling type
-@ 200 ns/div...
Real time
360 s/div:
-@ 5 ns/div...
Equivalent time
100 ns/div:
Maximum
sampling
rate
-Real time:
250 megasamples/s
~Equivalent time:
10 gigasamples/s
~Ext. clock
50 kilosamptes/s
Vertical (=voltage)
10 bits
resolution
Horizontal (=time)
resolution
-in single Ch. or
added Ch.
acquisition
@ t ms/div...
4096 samp./acquisition
5 s/div
@ 5 ns/div...
512 samp./acquisition
500 us/div
-In dual channel
acquisition
@ 1 ms/div...
2048 samp./acauisition
5 s/div
@ 5 ns/div...
512 samp./acquisition
500 us/div
ADDITIONAL
INFORMATION
Common
screwdriver control
on front for trace and
text.
Screw driver control on
front; direction of screw
driver rotation same as
direction of trace
rotation.
Either X or Y trace can
be aligned with graticule,
when environmental
magnetic field is within
0,1 mT.
Random
sampling.
Sampling rate depends on
time/div setting.
Repetitive only.
Max. aperture uncertainty
of 10 us.
(= 0,1 % of full range).
1 Sample = 0,025 % of
full record.
1 Sample = 0,2 % of
full record.
1 Sample = 0,05 % of
full record.
1 Sample = 0,2 % of
full record.