2.4

Controls and Indicators

• Trigger Pressure Control: Selects the dynamic triggering pressure; calibrated 1-24 in half-
steps (48 detents) corresponding to a force range of 15-200 lbs. (67-890 N) for the higher force
units and 7-200 lbs. (32-890 N) for the lower force units. For more information, see
Trigger
Mechanism.
The front panel controls on the 2000Xae Actuator are listed below:
• Power Light: Indicates that the Actuator is connected to the Power Supply and that the Power
Supply's main power is on
• Pressure Gauge: Indicates the amount of factory air pressure applied to the cylinder; dual
graduated at 0-100 psi and 0-700 kPa
• Pressure Regulator: Adjust the amount of air pressure applied to the cylinder; range of 5-100
psig (35-700 kPa). Pull to set; push to lock
• Carriage Door: Provides access to the converter-booster-horn stack; secured by four captive
hex screws. Use an M5 T-handle wrench to tighten the cap screws for the 2000X aed Actuator.
Use an M8 T-handle wrench to tighten the cap screws for the 2000X aed 15 kHz Actuator
• Mechanical Stop: Limits the stroke length to prevent the horn from contacting the fixture when
no workpiece is in place. The adjustment is approximately 0.07 in (1.75 mm) per rotation for the
2000X ae 15 kHz Actuator, and approximately 0.04 in (1 mm) per rotation for the 2000X
Actuator. A locking ring keeps the setting from vibrating loose. Turning the knob clockwise
increases the stroke length
NOTICE
CAUTION
1019571 REV. 03
The mechanical stop is not intended for welding by distance.
Turning the mechanical stop too far can cause it to come apart.
Dynamic
19