Figure 4.13 Rear View Of 2000X 15 Khz Ae Actuator, Showing Mounting Surface, Bolt And Guide Pin Locations - Emerson Branson 2000X ae Operating Manual

Table of Contents

Advertisement

Figure 4.13 Rear View of 2000X 15 kHz ae Actuator, showing Mounting Surface, Bolt and Guide Pin
Locations
4.5.4
Mount the Power Supply
The power supply is designed to be placed on a workbench (rubber feet on bottom) within
cable-length limits of the actuator, or it may be rack-mounted in a standard 19-inch Rack
(using an optional rack mount handle kit). It has two rear-mounted fans which draw
cooling air from rear to front, which must be free from obstruction. Do not place the power
supply on the floor or in other locations that will allow dust, dirt or contaminants to be
drawn into the power supply.
The controls on the front of the power supply must be accessible and readable for setup
changes.
All electrical connections are made to the rear of the power supply, which should be
positioned in your workspace with adequate clearance (approximately 4 inches or more on
either side, and 6 inches to the rear) for cable access and ventilation. Do not place
anything on top of the power supply case.
1019571 REV. 03
148
AIR INLET
1/4" DIA TUBING
M10x1.5 THDS
10mm DEEP (3 PLACES)
MACHINED MOUNTING
SURFACE (3 PLACES)