Figure 148. Installing the PCIe riser cage
Step 2.
Rotate the handle all the way down to secure the cage to the server.
After this task is completed
Proceed to complete the parts replacement (see
Demo video
Watch the procedure on YouTube
4U PCIe riser power cable assembly replacement
Follow instructions in this section to remove or install the 4U PCIe riser power cable assembly.
Remove 4U PCIe riser power cable assembly
Follow instructions in this section to remove 4U PCIe riser power cable assembly.
About this task
Attention:
• Go over
"Installation Guidelines" on page 137
• Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
"Power off the server" on page
• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack.
Procedure
Step 1.
Make preparations for this task.
a.
Remove the top cover (see
b.
Remove both PCIe riser cages or fillers, the chassis air baffle, and the PCIe expansion tray (see
"Remove a 4U PCIe riser cage" on page
"Remove the 4U PCIe expansion tray" on page
Step 2.
Flip the 4U PCIe expansion tray upside down.
Step 3.
Loosen the captive screws to disengage the modules.
ThinkSystem SR860 V2 Maintenance Manual
260
"Complete the parts replacement" on page
to ensure that you work safely.
12).
"Remove the top cover" on page
255,
240).
"Remove the chassis air baffle" on page
249).