• Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
"Power off the server" on page
• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack.
Procedure
Step 1.
If a drive filler has been installed in the drive bay, remove it.
Figure 159. Removing 7mm drive fillers
Step 2.
Gently rotate the release latch away to unlock the drive handle.
Figure 160. Installing 7mm drives
Step 3.
Slide the drive into the drive bay, and push it until it stops.
Step 4.
Rotate the handle back to the locked position.
After this task is completed
Check the drive status LED to verify if the drive is operating correctly:
• If the yellow LED is lit continuously, it is malfunctioning and must be replaced.
• If the green LED is flashing, the drive is functioning.
12).
.
Chapter 4
Hardware replacement procedures
269