Figure 39. Drive backplane numbering
Table 23. Drive backplanes and corresponding drive bays
Drive backplane Drive bay
1
1
2
2
3
3
4
4
5
5
6
6
Notes: When the following components are installed in the system, bay 24 to 47 are disabled, and the
maximal supported drive quantity is 24.
• PMEMs
• DRAM DIMMs with 64 GB or larger capacity
• Processors with 250 or more watts
For a complete list of supported optional device for this server, see
Procedure
Step 1.
If a drive filler has been installed in the drive bay, remove it.
Step 2.
Gently rotate the release latch away to unlock the drive handle.
Step 3.
Slide the drive into the drive bay, and push it until it stops.
Supported drive backplane
0 to 7
• 2.5-inch SAS/SATA 8-bay
8 to 15
drive backplane
16 to 23
• 2.5-inch AnyBay/NVMe 8-
bay drive backplane
24 to 31
• 2.5-inch SAS/SATA 8-bay
32 to 39
drive backplane
40 to 47
Supported drive
• 2.5-inch SAS/SATA
drives
• 2.5-inch NVMe drives
• 2.5-inch SAS/SATA
drives
https://serverproven.lenovo.com/
.