Safety logic edit (robot controller)

8.1.8
Set the safety logic of the robot controller.
・ When safety input SCNI01 is OFF, the SS1 function is activated.
・ When MODE input is AUTO, the SLS1 function is activated.

Safety monitoring function settings (robot controller)

8.1.9
Set the safety monitoring function of the robot controller.
Function
Item
SLS1
XYZ monitoring speed
> Composite speed
Fig. 8-5: Safety logic setting example (safety input)
Table 8-4 Safety monitoring function settings
8 SYSTEM APPLICATION EXAMPLES
Setting value
2000 [mm/s]
Remarks
-