Mitsubishi Electric CR800-R Instruction Manual page 147

Industrial robot, safety communication function
Hide thumbs Also See for CR800-R:
Table of Contents

Advertisement

The following shows calculation examples.
Item
Description
DTin
Input device response time
DTtrs
Safety data transmission time (maximum value)
DTout
Output device response time
Trrc
Robot controller response time
Tmax
Maximum stopping time
DTout = Trrc + Tmax
SFRT = DTin + DTtrs + DTout
= DTin + DTtrs + Trrc + Tmax
= DTin + 87.5 + 7.11 + Tmax
= DTin + Tmax + 95 [ms]
Table 8-18 Parameters
8 SYSTEM APPLICATION EXAMPLES
Value
Remarks
-
Input device
specifications
87.5[ms]
Value from the
above formula
-
Shown below
7.11[ms]
-
-
-
Application Example 2 8-135