7 SAFETY RESPONSE TIME AND SAFE STOPPING DISTANCE
RH-12FRH
Stopping time and stopping distance (emergency stop)
Axis
Arm extension
L=100%
J1
L=66%
L=33%
J2
-
J3
-
J4
-
Stopping time and stopping distance (power off)
Axis
Arm extension
J1
L=100%
J2
L=100%
J3
-
J4
-
7-110 Maximum Stopping Time and Maximum Operating Angle
Load rate
Ovrd 33%
M=100%
0.48
M=66%
0.42
M=33%
0.35
M=0%
0.32
M=100%
0.48
M=66%
0.42
M=33%
0.35
M=0%
0.29
M=100%
0.48
M=66%
0.42
M=33%
0.35
M=0%
0.26
M=100%
0.47
M=66%
0.42
M=33%
0.36
M=0%
0.34
M=100%
0.51
M=66%
0.43
M=33%
0.33
M=0%
0.29
Load 2
0.48
Load 1
0.38
Stopping time [s]
Load rate
Ovrd 100%
M=100%
M=25%
M=100%
M=25%
M=100%
M=25%
Load 2
Load 1
Stopping time [s]
Ovrd 66%
Ovrd 100%
0.50
0.51
0.44
0.46
0.38
0.40
0.35
0.38
0.50
0.51
0.44
0.46
0.37
0.40
0.31
0.34
0.50
0.51
0.44
0.46
0.37
0.40
0.29
0.32
0.50
0.54
0.47
0.52
0.42
0.49
0.40
0.47
0.55
0.59
0.47
0.52
0.37
0.42
0.33
0.38
0.50
0.51
0.41
0.43
Stopping distance [deg]
Ovrd 100%
0.62
0.59
0.66
1.26
109.27
0.68
269.73
0.19
150.08
1.95
281.87
0.68
269.73
Stopping distance
J1/J2/J4 axis [deg]
J3 axis [mm]
Ovrd 33%
Ovrd 66%
18.28
37.61
22.86
47.82
24.63
52.72
23.82
51.49
18.28
37.61
22.86
47.82
24.46
52.37
21.51
46.85
18.28
37.61
22.86
47.82
24.46
52.37
19.79
43.42
18.94
40.59
24.31
54.06
27.07
63.14
26.72
63.44
216.09
466.05
191.96
421.11
156.10
352.91
142.90
329.70
95.32
195.56
155.60
332.07
24.55
38.17
57.68
Ovrd 100%
58.60
75.71
85.28
84.01
58.60
75.71
84.75
76.99
58.60
75.71
84.75
71.79
65.72
90.40
109.73
111.73
759.02
696.11
598.29
568.10
303.97
535.73