Mitsubishi Electric FR-S500E Instruction Manual page 64

Frequency inverter
Table of Contents

Advertisement

Function (Parameter) list
Func-
Para-
Indica-
tion
meter
tion
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
Name
Setting Range
Multi-speed
setting
0 to 120Hz, - - -
(speed 12)
Multi-speed
setting
0 to 120Hz, - - -
(speed 13)
Multi-speed
setting
0 to 120Hz, - - -
(speed 14)
Multi-speed
setting
0 to 120Hz, - - -
(speed 15)
PID action
20: PID reverse action,
selection
21: PID forward action
PID
proportional
0.1 to 999%, - - -
band
PID integral
0.1 to 999s, - - -
time
PID upper
0 to 100%, - - -
limit
PID lower
0 to 100%, - - -
limit
PID action set
point for PU
0 to 100%
operation
PID
differential
0.01 to 10s, - - -
time
Rated motor
0 to 50%, - - -
slip
Slip
compensation
0.01 to 10s
time constant
Constant-
output region
slip
0, - - -
compensation
selection
Automatic
torque boost
selection
0.1 to 3.7kW, - - -
(Motor
capacity)
Motor primary
0 to 50 , - - -
resistance
Minimum
Setting
Increments
0.1Hz
0.1Hz
0.1Hz
0.1Hz
1
0.1%
0.1s
0.1%
0.1%
0.01%
0.01s
0.01%
0.01s
1
0.01kW
0.01
54
Cus-
Factory
Refer
tomer
Setting
To:
Setting
- - -
64
- - -
64
- - -
64
- - -
64
20
111
100%
111
1s
111
- - -
111
- - -
111
0%
111
- - -
111
- - -
118
0.5s
118
- - -
118
- - -
119
- - -
120

Advertisement