Func-
Para-
Indica-
tion
meter
tion
41
42
43
44
45
46
47
48
49
50
51
Name
Setting Range
Up-to-
frequency
0 to 100%
sensitivity
Output
frequency
0 to 120Hz
detection
Output
frequency
detection for
0 to 120Hz, - - -
reverse
rotation
Second
acceleration/
0 to 999s
deceleration
time
Second
deceleration
0 to 999s, - - -
time
Second
0 to 15%, - - -
torque boost
Second V/F
(base
0 to 120Hz, - - -
frequency)
Output current
0 to 200%
detection level
Output current
detection
0 to 10s
period
Zero current
detection
0 to 200%
level
Zero current
detection
0.05 to 1s
period
Minimum
Setting
Increments
1%
0.1Hz
0.1Hz
0.1s
0.1s
0.1%
0.1Hz
1%
0.1s
1%
0.01s
49
Function (Parameter) list
Cus-
Factory
Refer
tomer
Setting
To:
Setting
10%
84
6Hz
85
- - -
85
5s
65
- - -
65
- - -
61
- - -
63
150%
86
0s
86
5%
87
0.5s
87
2