Daikin EBLA04E V Series Service Manual page 154

Table of Contents

Advertisement

4
|
Components
Service manual
154
draft – 31/05/2022 15:53
a Compressor wire terminals cover
3 Disconnect the Faston connectors from the compressor wire terminals U, V
and W.
INFORMATION
Note the position of the Faston connectors on the compressor wire terminals to
allow correct connection during installation.
U Wire terminal U
V Wire terminal V
W Wire terminal W
4 Remove the compressor thermal protector, see
4
thermal
protector" [
5 Supply nitrogen to the refrigerant circuit. The nitrogen pressure MUST NOT
exceed 0.02 MPa.
6 Wrap a wet rag around the components near the compressor pipes. Heat the
brazing points of the compressor pipes using an oxygen acetylene torch and
remove the refrigerant pipes from the compressor pipes using pliers.
a
V
U
W
 160].
"To remove the compressor
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05

Advertisement

Table of Contents
loading

Table of Contents