EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
3 Remove
the
backup
4
procedures" [
 136].
4 Unscrew and remove the air purge valve. Keep for reuse.
5 Remove the clip from the upper backup heater pipe.
d
c
a Backup heater thermal protector sensor
b Air purge valve
c Clip (upper backup heater pipe)
d Clip (backup heater coupling)
e Upper backup heater coupling
f Backup heater
g Bracket
6 Remove the clip from the upper backup heater coupling.
7 Remove the clip from the lower backup heater pipe.
8 Remove the clip from the lower backup heater coupling.
b
a
c
a Clip (lower backup heater pipe)
b Clip (backup heater coupling)
c Lower backup heater coupling
d Backup heater
e Bracket
9 Separate the upper and lower backup heater coupling.
heater
thermal
g
a
b
e
f
d
e
draft – 31/05/2022 15:53