QuickSpecs

Technical Specifications

System Unit
Server Dimensions
(L x W x D)
Shipping
Dimensions
(L x W x D)
Weight
(approximate)
System Inlet
Temperature
Relative Humidity
(non-condensing)
1.70 x 8.33 x 27.87 in (4.33 x 21.15 x 70.79 cm)
37.63 x 15.13 x 9 in (95.5 x 38.4 x 22.8 cm)
Maximum
(four hard drives and one
processor installed)
Standard Operating
Support
Extended Ambient
Operating Support
Non-operating
Operating
HPE ProLiant XL260a Gen9 Server
11.0 lb (4.99 kg)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
20°C/hr (36°F/hr). The upper limit and rate of
change may be limited by the type and number
of options installed.
System performance during standard operating
support may be reduced if operating with a fan
fault or above 30°C (86°F).
For approved hardware configurations, the
supported system inlet range is extended to be:
5° to 10°C (41° to 50°F) and 35° to 40°C (95° to
104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft)
above 900 m (2953 ft) to a maximum of 3050 m
(10,000 ft). The approved hardware
configurations for this system are listed at the
URL:
http://www.hp.com/servers/ASHRAE
For approved hardware configurations, the
supported system inlet range is extended to be:
40° to 45°C (104° to 113°F) at sea level with an
altitude derating of 1.0°C per every 125 m
(1.8°F per every 410 ft) above 900 m (2953 ft)
to a maximum of 3050 m (10,000 ft). The
approved hardware configurations for this
system are listed at the URL:
http://www.hp.com/servers/ASHRAE
System performance may be reduced if
operating in the extended ambient operating
range or with a fan fault.
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Minimum to be the higher (more moisture) of -
12°C (10.4°F) dew point or 8% relative
humidity. Maximum to be the lower (less
Page 16