Technical Specifications - HPE Apollo 480 Hardware User's Manual

Table of Contents

Advertisement

Technical Specifications

This appendix contains technical specification information about your system.
System Specifications and Features
The table following lists the physical and electrical specifications of the HPE Apollo 480 Cluster.
System Features
Cabinet height
Cabinet width
Cabinet depth
Weight (full) maximum
Phase required
Voltage and CPS range
Power cables
Power supplies
Cooling
Hard drive bays
PCIe slots
Environmental Specifications
The table following lists the environmental specifications of the Apollo 480 system.
Feature
Temperature tolerance (operating)
Temperature tolerance (nonoperating)
Relative humidity
Cooling requirement
Maximum altitude
Acoustical noise level (sound pressure)
14
Technical Specifications
Specification
85.6 in. (217.4 cm)
24 in. (61 cm)
48 in. (121.9)
Approximately 2,579 lbs. Shipping weight will be
greater.
Four three-phase PDUs per rack
North America - nominal voltage is 208V at 24A per
phase (50/60hz for 3W+PE)
Europe - nominal voltage is 415V at 30A per phase
(50/60hz for 3W+ N+PE)
Four three-phase pluggable cords per rack
Two per compute enclosure (2000W minimum per
power supply)
Compute enclosure fans (40mm x4 per enclosure)
Up to 2 per node, up to 48 in front bay
Optional low-profile (x16) PCI-Express slots on
HPC compute nodes
Specification
+5°C (45°F) to +35°C (95°F) (up to 1500 m / 5000
ft.)
-40°C (-41°F) to +60°C (140°F)
20% to 80% operating (no condensation)
8% to 80% nonoperating (no condensation)
Ambient air cooling
10,000 ft. (3,049 m) operating
40,000 ft. (12,195 m) nonoperating
Less than 90 dBA maximum