2.8 Installing and replacing feed rolls
Replace the feed rolls when the filler wire diameter or material changes. Select the feed rolls according to the tables in
"Wire feeder consumables" on page 74.
1.
Open the wire feed cabinet hatch.
2.
Release the pressure handles on the wire feed mechanism.
3.
Open the locking arms to release the feed rolls.
4.
Pull the pressure roll mounting pins and drive roll mounting caps off.
© Kemppi
26
Master M 353, 355
Operating manual - EN
1921960 / 2307