Kemppi Master M 353 Operating Manual page 63

Table of Contents

Advertisement

40
VRD error
42
High current in
wire feeder
motor
43
Overcurrent in
wire feeder
motor
44
Wire speed
measurement is
missing
Low gas pres-
45
sure
61
Operation is not
allowed
Subfeeder not
65
allowed
244
Internal memory
failure
250
Internal memory
failure
© Kemppi
Open circuit voltage exceeds the VRD limit.
There may be too much pressure in the
wire feed rolls or dirt in the wire line.
There may be too much pressure in the
wire feed rolls or dirt in the wire line.
Faulty sensor or wiring in wire feeder.
Shielding gas pressure is too low.
Subfeeder is connected, but it has not been
selected in the system settings.
Use of subfeeder is not allowed with selec-
ted welding process.
Initialization failed (%sub:%device).
Memory communication failed (%sub-
:%device).
Restart the power source. If problem persists, contact
Kemppi service.
Adjust the feed roll pressure. Clean the wire line.
Change worn parts in the welding gun.
Adjust the feed roll pressure. Clean the wire line.
Change worn parts in the welding gun.
Restart the welding system. If problem persists, con-
tact Kemppi service.
Check and adjust the shielding gas flow.
Go to the system settings menu on the control panel
and select your subfeeder model and type.
Remove the subfeeder or change the welding pro-
cess.
Restart welding system. If problem persists, contact
Kemppi service.
Restart welding system. If problem persists, contact
Kemppi service.
63
Master M 353, 355
Operating manual - EN