About the Power button LED states
System Status LED states (continued)
Table 1-5
Color
State
Amber
Solid on
Amber
Solid on
The Power button is located on the Veritas 5250 Appliance control panel. It is used
to turn the appliance on and off.
About the 5250 Appliance control panel
Criticality
Description
Critical,
Fatal alarm – system has failed or shutdown:
non-recoverable
CPU CATERR signal asserted
■
– System is
MSID mismatch detected (CATERR also
■
halted
asserts for this case)
CPU1 is missing
■
CPU Thermal Trip
■
No power – power fault
■
DIMM failure when there is only one DIMM
■
present; no other good DIMM memory
present
Runtime memory uncorrectable error in
■
non-redundant mode.
Critical,
Uncorrectable Runtime memory error in
■
non-recoverable
non-redundant mode
– System is
DIMM Thermal Trip or equivalent
■
halted
CPU ERR2 signal is asserted
■
BMC/Video memory test failed (Chassis ID
■
shows blue/solid-on for this condition)
SBB Thermal Trip or equivalent
■
240VA fault
■
Both uBoot BMC FW images are bad
■
(Chassis ID shows blue/solid-on for this
condition)
Fatal Error in processor initialization:
■
■
■
■
■
■
■
About the Veritas 5250 Appliance
Processor family not identical
Processor model not identical
Processor core/thread counts not identical
Processor cache size not identical
Unable to synchronize processor
frequency
Unable to synchronize QPI link frequency
18