VERITAS 5250 Product Description Manual page 42

Table of Contents

Advertisement

Veritas S Series 2U12 65.5TiB/72TB Storage Shelf control panel
Table 2-3
functions
Number
Item
1
Input switch
2
Power On / Standby LED
(Green or Amber)
3
Module Fault LED (Power
Cooling Module, Cooling,
I/O module status) (Amber)
4
Logical status LED (amber)
5
Unit Identification Display
S Series Control panel LED conditions and statuses
Table 2-4
System
Module
Power
Fault
(Amber)
(Green or
Amber)
On (Amber)
Off
On (Green)
On (Amber)
On (Green)
Off
Veritas 2U12 65.5TiB/72TB Storage Shelf
Components of the S Series Storage Shelf
Description
The Input switch enables you to set the Unit
Identification display.
The Power On/Standby LED shows Amber when
only standby power is available. Otherwise, the LED
shows Green when system power is available.
The Module Fault LED illuminates when there is a
system hardware fault. The system hardware fault
may be associated with a fault LED on a Power
Cooling Module (PCM) or on an I/O module.
The Logical Status LED shows a change of status
or a fault. Typically these changes of status or faults
are associated with the shelf's disk drives. However,
the Logical Status LED can also indicate an issue
with an internal RAID controller or external RAID
controller, or with a host bus adapter.
The Unit Identification Display is a dual digit display
that provides information about the storage shelf.
Its primary function is to assist in the configuration
of multiple storage shelves.
Logical
Associated
Fault
LEDs/Alarms
(Amber)
Off
None
N/A
Single beep,
then double
beep
Off
None
Status
Standby power present,
Overall Power failed or
switched off
Control Panel Power on - test
state
(Test state = 5 seconds)
Power On - All functions good
42