Parameter list

4.2
Parameter list
4.2.1
Parameter list
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used. Set the necessary
parameters to meet the load and operational specifications. Parameter setting, change and check can be made from the
operation panel.
REMARKS
  indicates simple mode parameters.
 The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in Pr. 77 Parameter write selection.
Parameter
Name
 0
Torque boost
 1
Maximum frequency
 2
Minimum frequency
 3
Base frequency
 4
Multi-speed setting (high speed)
 5
Multi-speed setting (middle speed)
 6
Multi-speed setting (low speed)
 7
Acceleration time
 8
Deceleration time
 9
Electronic thermal O/L relay
10
DC injection brake operation frequency 0 to 120Hz
11
DC injection brake operation time
12
DC injection brake operation voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High speed maximum frequency
19
Base frequency voltage
Acceleration/deceleration reference
20
frequency
22
Stall prevention operation level
Stall prevention operation level
23
compensation factor at double speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
Acceleration/deceleration pattern
29
selection
60
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 30%
0.1%
6/4/3/2%
77

0 to 120Hz
0.01Hz
120Hz
86
0 to 120Hz
0.01Hz
0Hz
86
0 to 400Hz
0.01Hz
60Hz
88
0 to 400Hz
0.01Hz
60Hz
92
0 to 400Hz
0.01Hz
30Hz
92
0 to 400Hz
0.01Hz
10Hz
92
0 to 3600s
0.1s
5/10/15s

99
0 to 3600s
0.1s
5/10/15s

99
Inverter
0 to 500A
0.01A
rated
103
current
0.01Hz
3Hz
112
0 to 10s
0.1s
0.5s
112
0 to 30%
0.1%
6/4/2%
112

0 to 60Hz
0.01Hz
0.5Hz
101
0 to 3
1
0
90
0 to 400Hz
0.01Hz
5Hz
94
0 to 3600s
0.1s
0.5s
94
0, 2, 4
1
0
118
120 to 400Hz
0.01Hz
120Hz
86
0 to 1000V, 8888, 9999
0.1V
9999
88
1 to 400Hz
0.01Hz
60Hz
99
0 to 200%
0.1%
150%
82
0 to 200%, 9999
0.1%
9999
82
0 to 400Hz, 9999
0.01Hz
9999
92
0 to 400Hz, 9999
0.01Hz
9999
92
0 to 400Hz, 9999
0.01Hz
9999
92
0 to 400Hz, 9999
0.01Hz
9999
92
0, 1, 2
1
0
102
 Symbol in the Remarks column
...Specifications differ according to the date assembled. Refer to page 301 to check the SERIAL number.
 These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 184 for RS-485 communication.)
 "" indicates valid and "" indicates invalid of "control mode-based correspondence table", "parameter copy", "parameter clear", and "all parameter clear".
Customer
Parameter
Remarks
Setting
 0
 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
22
23
24
25
26
27
29
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
Copy
00
80
0
01
81
0
02
82
0
03
83
0
04
84
0
05
85
0
06
86
0
07
87
0
08
88
0
09
89
0
0A
8A
0
0B
8B
0
0C
8C
0
0D
8D
0
0E
8E
0
0F
8F
0
10
90
0
11
91
0
12
92
0
13
93
0
14
94
0
16
96
0
17
97
0
18
98
0
19
99
0
1A
9A
0
1B
9B
0
1D
9D
0
Parameter list
Parameter
Clear
All clear
4

Advertisement

Table of Contents
loading

Table of Contents