Mitsubishi Electric FR-D720 K Series Instruction Manual page 75

Table of Contents

Advertisement

Parameter list
Parameter
Name
251
Output phase loss protection selection
255
Life alarm status display
256
Inrush current limit circuit life display
257
Control circuit capacitor life display
258
Main circuit capacitor life display
259
Main circuit capacitor life measuring
260
PWM frequency automatic switchover
261
Power failure stop selection
267
Terminal 4 input selection
268
Monitor decimal digits selection
269
Parameter for manufacturer setting. Do not set.
295
Magnitude of frequency change setting
296
Password lock level
297
Password lock/unlock
298
Frequency search gain
Rotation direction detection selection
299
at restarting
Communication operation command
338
source
Communication speed command
339
source
340
Communication startup mode selection
Communication EEPROM write
342
selection
343
Communication error count
450
Second applied motor
495
Remote output selection
496
Remote output data 1
502
Stop mode selection at communication error
503
Maintenance timer
504
Maintenance timer alarm output set time
549
Protocol selection
PU mode operation command source
551
selection
552
Frequency jump range
555
Current average time
556
Data output mask time
Current average value monitor signal
557
output reference current
561
PTC thermistor protection level
68
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0, 1
1
1
149
(0 to 15)
1
0
230
(0 to 100%)
1%
100%
230
(0 to 100%)
1%
100%
230
(0 to 100%)
1%
100%
230
0, 1 (2, 3, 8, 9)
1
0
230
0, 1
1
0
151
0, 1, 2
1
0
145
0, 1, 2
1
0
153
0, 1, 9999
1
9999
131
0, 0.01, 0.10, 1.00,
0.01
0
241
10.00
1 to 6, 101 to 106, 9999
1
9999
166
1000 to 9998 (0 to 5,
1
9999
166
9999)
0 to 32767, 9999
1
9999
139
0, 1, 9999
1
0
139
0, 1
1
0
177
0, 1, 2
1
0
177
0, 1, 10
1
0
176
0, 1
1
0
188
1
0
201
0, 1, 9999
1
9999
106
0, 1, 10, 11
1
0
129
0 to 4095
1
0
129
185,
0, 1, 2
1
0
201
0 (1 to 9998)
1
0
234
0 to 9998, 9999
1
9999
234
0, 1
1
0
201
2, 4, 9999
1
9999
177
0 to 30Hz, 9999
0.01Hz
9999
87
0.1 to 1s
0.1s
1s
235
0 to 20s
0.1s
0s
235
Inverter
0 to 500A
0.01A
rated
235
current
0.5 to 30k , 9999
0.01k
9999
103
Customer
Parameter
Remarks
Setting
251
255
256
257
258
259
260
261
267
268
269
Parameter for manufacturer setting. Do not set.
295
296
297
298
299
338
339
340
342
343
450
495
496
502
503
504
549
551
552
555
556
557
561
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
Copy
3B
BB
2
3F
BF
2
40
C0
2
41
C1
2
42
C2
2
43
C3
2
44
C4
2
45
C5
2
4B
CB
2
4C
CC
2
67
E7
2
68
E8
2
69
E9
2
6A
EA
2
6B
EB
2
26
A6
3
27
A7
3
28
A8
3
2A
AA
3
2B
AB
3
32
B2
4
5F
DF
4
60
E0
4
02
82
5
03
83
5
04
84
5
31
B1
5
33
B3
5
34
B4
5
37
B7
5
38
B8
5
39
B9
5
3D
BD
5
Parameter list
Parameter
Clear
All clear






4





Advertisement

Table of Contents
loading

Table of Contents