Mitsubishi Electric FR-D720 K Series Instruction Manual page 303

Table of Contents

Advertisement

Item
Pr. 52 Control panel display data selection
1: Output current
Pr.54 FM terminal function selection
0: Output frequency (initial value),
1: Output current
Pr. 60 to Pr. 63 Input terminal function selection
5: STOP signal (start self-holding selection)
6: MRS signal (output stop)
Changed setting value
9: JOG signal (Jog operation selection)
10: RES signal (reset)
---: STR signal (reverse rotation command)
Second applied motor
Pr. 71 = 100, 101
Pr. 73 Terminal 2 0 to 5V, 0 to 10V selection
0: 0 to 5V (initial value),
1: 0 to 10V
Pr. 98 Automatic torque boost selection
Deleted functions
Pr. 99 Motor primary resistance
Long wiring mode (setting value 10, 11 of Pr. 70)
FR-S500
FR-D700
Pr.52 DU/PU main display data selection
0/100: Output current (select with
1: Output frequency (initial value),
2: Output current
Pr. 178 to Pr. 182 Input terminal function selection
5: JOG signal (Jog operation selection)
6: None
24: MRS signal (output stop)
25: STOP signal (start self-holding selection)
61: STR signal (reverse rotation command)
62: RES signal (reset)
Pr. 450 Second applied motor
Pr. 73 Analog input selection
0: 0 to 10V,
1: 0 to 5V (initial value)
Replacement function (General-purpose magnetic flux
vector control)
(Pr. 80 Motor capacity)
(Pr. 90 Motor constant (R1))
Setting unnecessary (setting value 10, 11 of Pr. 240 is
deleted)
)
299