Mitsubishi Electric FR-D720 K Series Instruction Manual page 304

Table of Contents

Advertisement

Item
Parameter
Number
Pr. 17
Pr. 21
Pr. 28
Pr. 30
Pr. 38
Pr. 39
Pr. 40
Pr. 48
Pr. 49
Pr. 50
Pr. 51
Pr. 53
Pr. 60
Pr. 61
Pr. 62
Pr. 63
Pr. 64
Pr. 65
Pr. 66
Pr. 70
Pr. 76
Pr. 80
Pr. 81
Changed parameter
Pr. 82
Pr. 83
number and name
Pr. 84
Pr. 85
Pr. 86
Pr. 87
Pr. 88
Pr. 89
Pr. 90
Pr. 91
Pr. 92
Pr. 93
Pr. 94
Pr. 95
Pr. 96
Pr. 97
H7(Pr. 559)
b1(Pr. 560)
b2(Pr. 561)
n1(Pr. 331)
n2(Pr. 332)
n3(Pr. 333)
n4(Pr. 334)
n5(Pr. 335)
n6(Pr. 336)
n7(Pr. 337)
n11(Pr. 341) CR/LF setting
n16(Pr. 992) PU main display screen data selection
n17(Pr. 993) Disconnected PU detection/PU setting lock Pr. 75
Screw type terminal block
Fix a wire with a flathead screw
Control terminal block
(Screw size: M2(M3 for terminal A, B, C))
Length of recommended blade terminal: 6mm
PU
FR-PU04
FR-D720-0.1K to 3.7K, FR-D740-0.4K to 3.7K, FR-D720S-0.1K to 1.5K, FR-D710W-0.1K to 0.75K are compatible in
Installation size
mounting dimensions
300
FR-S500
Name
RUN key rotation direction selection
Stall prevention function selection
Stall prevention operation reduction
starting frequency
Extended function display selection
Frequency setting voltage gain frequency
Frequency setting current gain frequency
Start-time ground fault detection selection
Output current detection level
Output current detection signal delay time
Zero current detection level
Zero current detection time
Frequency setting operation selection
RL terminal function selection
RM terminal function selection
RH terminal function selection
STR terminal function selection
RUN terminal function selection
A, B, C terminal function selection
Retry selection
Soft-PWM setting
Cooling fan operation selection
Multi-speed setting (speed 8)
Multi-speed setting (speed 9)
Multi-speed setting (speed 10)
Multi-speed setting (speed 11)
Multi-speed setting (speed 12)
Multi-speed setting (speed 13)
Multi-speed setting (speed 14)
Multi-speed setting (speed 15)
PID action selection
PID proportional band
PID integral time
PID upper limit
PID lower limit
PID action set point for PU operation
PID differential time
Rated motor slip
Slip compensation time constant
Constant power range slip compensation
selection
Second electronic thermal O/L relay
Regenerative function selection
Special regenerative brake duty
Communication station number
Communication speed
Stop bit length
Parity check presence/absence
Number of communication retries
Communication check time interval
Waiting time setting
FR-D700
Parameter
Number
Pr. 40
RUN key rotation direction selection
Pr. 156
Stall prevention operation selection
Stall prevention operation reduction
Pr. 66
starting frequency
Pr. 160
Extended function display selection
Terminal 2 frequency setting gain
Pr. 125
frequency
Terminal 4 frequency setting gain
Pr. 126
frequency
Pr. 249
Earth (ground) fault detection at start
Pr. 150
Output current detection level
Pr. 151
Output current detection signal delay time
Pr. 152
Zero current detection level
Pr. 153
Zero current detection time
Frequency setting/key lock operation
Pr. 161
selection
Pr. 180
RL terminal function selection
Pr. 181
RM terminal function selection
Pr. 182
RH terminal function selection
Pr. 179
STR terminal function selection
Pr. 190
RUN terminal function selection
Pr. 192
A,B,C terminal function selection
Pr. 65
Retry selection
Pr. 240
Soft-PWM operation selection
Pr. 244
Cooling fan operation selection
Pr. 232
Multi-speed setting (speed 8)
Pr. 233
Multi-speed setting (speed 9)
Pr. 234
Multi-speed setting (speed 10)
Pr. 235
Multi-speed setting (speed 11)
Pr. 236
Multi-speed setting (speed 12)
Pr. 237
Multi-speed setting (speed 13)
Pr. 238
Multi-speed setting (speed 14)
Pr. 239
Multi-speed setting (speed 15)
Pr. 128
PID action selection
Pr. 129
PID proportional band
Pr. 130
PID integral time
Pr. 131
PID upper limit
Pr. 132
PID lower limit
Pr. 133
PID action set point
Pr. 134
PID differential time
Pr. 245
Rated slip
Pr. 246
Slip compensation time constant
Constant-power range slip compensation
Pr. 247
selection
Pr. 51
Second electronic thermal O/L relay
Pr. 30
Regenerative function selection
Pr. 70
Special regenerative brake duty
Pr. 117
PU communication station number
Pr. 118
PU communication speed
Pr. 119
PU communication stop bit length
Pr. 120
PU communication parity check
Pr. 121
Number of PU communication retries
Pr. 122
PU communication check time interval
Pr. 123
PU communication waiting time setting
Pr. 124
PU communication CR/LF selection
Pr.52
DU/PU main display data selection
Reset selection/disconnected PU
detection/PU stop selection
Spring clamp terminal block
Fix a wire with a pressure of inside spring
Length of recommended blade terminal: 10mm
(Blade terminal of FR-S500 is unavailable)
FR-PU07
FR-PU04 (some functions, such as parameter copy, are
unavailable.)
Name

Advertisement