Mitsubishi Electric FR-D720 K Series Instruction Manual page 215

Table of Contents

Advertisement

 Real time monitor
Refer to page 131 for details of the monitor description.
Register
Output frequency/speed 
40201
Output current 
40202
Output voltage 
40203
Output frequency setting/speed setting
40205

40208
Converter output voltage
40209
Regenerative brake duty
Electronic thermal relay function
40210
load factor
40211
Output current peak value
40212
Converter output voltage peak value
40214
Output power

When Pr.37 = "0.01 to 9998", displayed in integral number.

Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15

Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15

The monitored values are retained even if an inverter fault occurs. Resetting will clear the retained values.
....Specifications differ according to the date assembled. Refer to page 301 to check the SERIAL number.
 Parameter
Parameter
Register
41000 to
0 to 999
41999
C2 (902)
41902
42092
C3 (902)
43902
125 (903)
41903
42093
C4 (903)
43903
C5 (904)
41904
42094
C6 (904)
43904
126 (905)
41905
42095
C7 (905)
43905
C22 (922)
41922
C23 (922)
42112
C24 (923)
41923
C25 (923)
42113
Description
Unit
0.01Hz/1
0.01A
0.1V
0.01Hz/1
0.1V
0.1%
0.1%
0.01A
0.1V
0.01kW
Parameter Name
Refer to the parameter list (page
60) for the parameter names.
Terminal 2 frequency setting
bias frequency
Terminal 2 frequency setting bias
(Analog value)
Terminal 2 frequency setting bias
(Terminal analog value)
Terminal 2 frequency setting gain
frequency
Terminal 2 frequency setting gain
(Analog value)
Terminal 2 frequency setting gain
(Terminal analog value)
Terminal 4 frequency setting bias
frequency
Terminal 4 frequency setting bias
(Analog value)
Terminal 4 frequency setting bias
(Terminal analog value)
Terminal 4 frequency setting
gain frequency
Terminal 4 frequency setting gain
(Analog value)
Terminal 4 frequency setting gain
(Terminal analog value)
Frequency setting voltage bias
frequency (built-in
potentiometer)
Frequency setting voltage bias
(built-in potentiometer)
Frequency setting voltage gain
frequency (built-in
potentiometer)
Frequency setting voltage gain
(built-in potentiometer)
Communication operation and setting
Register
40215
Input terminal status
40216
Output terminal status
40220
Cumulative energization time
40223
Actual operation time
40224
Motor load factor
40225
Cumulative power
40252
PID set point
40253
PID measured value
40254
PID deviation
40261
Motor thermal load factor
40262
Inverter thermal load factor
40263
Cumulative power 2
40264
PTC thermistor resistance
RH
RM
SO
ABC
Read/
Write
The parameter number + 41000 is the register
Read/write
number.
Read/write
Read/write The analog value (%) set to C3 (902) is read.
The analog value (%) of the voltage applied to the
Read
terminal 2 is read.
Read/write
Read/write The analog value (%) set to C4 (903) is read.
The analog value (%) of the voltage applied to the
Read
terminal 2 is read.
Read/write
Read/write The analog value (%) set to C6 (904) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write The analog value (%) set to C7 (905) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write The analog value (%) set to C23 (922) is read.
Read/write
Read/write The analog value (%) set to C25 (923) is read.
Description
Unit
1h
1h
0.1%
1kWh
0.1%
0.1%
0.1%
0.1%
0.1%
0.01kWh
0.01k
RL
STR
Remarks
b0
STF
b0
RUN
4
211

Advertisement

Table of Contents
loading

Table of Contents