Mitsubishi Electric FR-D720 K Series Instruction Manual page 73

Table of Contents

Advertisement

Parameter list
Parameter
Name
80
Motor capacity
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
90
Motor constant (R1)
96
Auto tuning setting/status
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting
124
PU communication CR/LF selection
 125
Terminal 2 frequency setting gain frequency
126
Terminal 4 frequency setting gain frequency
127
PID control automatic switchover frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
145
PU display language selection
146
Built-in potentiometer switching

150
Output current detection level
151
Output current detection signal delay time
152
Zero current detection level
153
Zero current detection time
Voltage reduction selection during stall
154
prevention operation
156
Stall prevention operation selection
157
OL signal output timer
 160
Extended function display selection
161
Frequency setting/key lock operation selection 0, 1, 10, 11
Automatic restart after instantaneous
162
power failure selection
Stall prevention operation level for
165
restart
64
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0.1 to 15kW, 9999
0.01kW
9999
78, 108
0 to 500A, 9999
0.01A
9999
108
200V/400V
0 to 1000V
0.1V
78, 108

10 to 120Hz
0.01Hz
60Hz
78, 108
0 to 50, 9999
0.001
9999
108
108,
0, 11, 21
1
0
139
184,
0 to 31 (0 to 247)
1
0
201
184,
48, 96, 192, 384
1
192
201
0, 1, 10, 11
1
1
184
184,
0, 1, 2
1
2
201
0 to 10, 9999
1
1
185
185,
0, 0.1 to 999.8s, 9999
0.1s
0
201
0 to 150ms, 9999
1ms
9999
184
0, 1, 2
1
1
184
0 to 400Hz
0.01Hz
60Hz
156
0 to 400Hz
0.01Hz
60Hz
156
0 to 400Hz, 9999
0.01Hz
9999
213
213,
0, 20, 21, 40 to 43
1
0
221
213,
0.1 to 1000%, 9999
0.1%
100%
221
213,
0.1 to 3600s, 9999
0.1s
1s
221
213,
0 to 100%, 9999
0.1%
9999
221
213,
0 to 100%, 9999
0.1%
9999
221
213,
0 to 100%, 9999
0.01%
9999
221
213,
0.01 to 10s, 9999
0.01s
9999
221
0 to 7
1
0
238
0, 1
1
1
243
0 to 200%
0.1%
150%
127
0 to 10s
0.1s
0s
127
0 to 200%
0.1%
5%
127
0 to 1s
0.01s
0.5s
127
1, 11
1
1
82
0 to 31, 100, 101
1
0
82
0 to 25s, 9999
0.1s
0s
82
0, 9999
1
9999
165
1
0
239
0, 1, 10, 11
1
1
139
0 to 200%
0.1%
150%
139
Customer
Parameter
Remarks
Setting
80
82
83
84
90
96
117
118
119
120
121
122
123
124
 125
 126
127
128
129
130
131
132
133
134
145
146
150
151
152
153
154
156
157
 160
161
162
165
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
Copy
50
D0
0
52
D2
0
53
D3
0
54
D4
0
5A
DA
0
60
E0
0
11
91
1
12
92
1
13
93
1
14
94
1
15
95
1
16
96
1
17
97
1
18
98
1
19
99
1
1A
9A
1
1B
9B
1
1C
9C
1
1D
9D
1
1E
9E
1
1F
9F
1
20
A0
1
21
A1
1
22
A2
1
2D
AD
1
2E
AE
1
32
B2
1
33
B3
1
34
B4
1
35
B5
1
36
B6
1
38
B8
1
39
B9
1
00
80
2
01
81
2
02
82
2
05
85
2
Parameter list
Parameter
Clear
All clear
















4

Advertisement

Table of Contents
loading

Table of Contents