KPM PROCESS SENSORS METIS M311 Operating Manual page 78

Pyrometers with 12-pin connector, led or oled display and push button device configuration versions with integrated optics, fiber optics, pid controller, ethernet ip-tcip / profibus / profinet.
Table of Contents

Advertisement

vm
X
vq
X
vt (vm)
X
In addition, for devices with built-in motorized focus
moa
XXXX
In addition, for devices with built-in PID controller
hz
XXXX
ob
XXXX
rg
X
ro
XX
r0 (ro0)
X
rz
XXXX
sg1
XXXX
sg2
XXXX
sw
XXXX
td
XXXXXX
ti
XXXXXX
xa
XXXX
xb
XXXX
xl
XXXX
xp
XXXX
ym
XXXX
ys
XXXX
yx
XXXX
In addition, for devices with Profibus / Profinet
fpa
XX
fbm
78
/ 81
METIS M311 / M322 / H311 / H322 (12-pin device connector)
Color transmission system camera module
X = 0 = NTSC; 1 = PAL
Image setting color / monochrome
X = 0 = color image; 1 = monochrome image
Test image:
X = 0 = normal image; 1 = test image
Focus distance
XXXX in mm (may be rounded up or down in 10 mm resolution!)
Hold time:
XXXX = 0x0000...ffff (in ms)
Next controller start with AutoTune
XXXX = 0x00C8...03E8 (20.0 to 100.0% in 0.1% steps)
Controller handle
X = 0 = Stop controller 1 = Start controller 3 = Controller with AutoTune
Controller options: Bit 0 = Clear of Ti (sets the integration sum of the PID control to 0
to prevent an undershoot if a control process is done from a higher to a lower value),
Bit 4 = AutoTune optimization at every control start
Controller options (not memory-resistant)
bit0 = next controller start with AutoTune
Ramp time in ms
XXXX = 0x0000...ffff
Temperature deviation from setpoint value ± 3000° for limit value 1
XXXX = 0x8AD0...7530 (in two's complement, 1/10 degree)
Temperature deviation from setpoint value ± 3000° for limit value 2
XXXX = 0x8AD0...7530 (in two's complement, 1/10 degree)
Setpoint value (XXXX in 1/10 degree)
Derivative time constant Td (in sampling times)
XXXXXX = 0x000000...00ffff
Integral time constant Ti (in sampling times)
XXXXXX = 0x000000...00ffff
Sampling time in 10 µs steps
M3: XXXX = 0x0064...09C4 (1 ms to 25 ms),
H3: XXXX = 0x000A...09C4 (0.1 ms to 25 ms)
Setpoint deviation (in 1/10 degree)
P dynamic
XXXX = 0x0000...2710 (0.01 to 100.00%; 0.01% steps)
Proportional band Xp
XXXX = 0x0000...2710 (0.1 to 1000.0%; 0.1% steps)
Minimum control output power Pmin
XXXX = 0x0000...03E7 (0.0 to 99.9%; 0.1% steps)
P-zs
XXXX = 0x0000...03E8 (0.0 to 100.0%; 0.1% steps)
P-max
XXXX = 0001...03E8 (0.1 to 100.0%; 0.1% steps)
Fieldbus address: 00...7fh (only Profibus)
Fieldbus mode (00, 01, 02)