5.6.1 Manually Adjusted or Motorized Focus Optics
Optics
M311 / H311:
OQ11-A1
M322 / H322:
OQ22-A2
M311: OQ11-F1
M322: OQ22-F2
Aperture diameter D: Full scale temperature value ≤ 1400 °C: 14-16 mm; > 1400 °C: 7-8 mm
(D is dependent on the optics pull-out: optics pulled out: higher value, optics inserted: smaller value)
5.6.2 Focusable Fiber-Optic Lenses
25 mm Optics
Std. 1" / 25 mm O.D.
M311 / H311:
OQ25-B1
M322 / H322:
OQ25-B2
Aperture diameter D: 10-13 mm
(D is dependent on the optics pull-out: optics pulled out: higher value, optics inserted: smaller value)
24
/ 81
Temperature ranges [°C]
Meas. distance
Optics pull-out
a [mm]
S [mm]
340
26
400
20.7
500
15.5
600
11.7
800
7.7
1000
5.5
1500
2.7
2000
1.3
2500
0.5
3000
1000
7.5
2000
3.3
3000
1.9
4000
1.2
5000
0.8
10000
Model
Temp. ranges [°C]
Meas. distance
a [mm]
240
300
400
500
600
700
800
1000
1500
2000
2500
3000
METIS M311 / M322 / H311 / H322 (12-pin device connector)
Model
M322: 300-1000°C
H311: FSC <1500°C
H322: FSC <1200°C
1.4
1.8
2.7
3.2
4.1
5.6
7.7
10
12.7
0
14
5.6
10
14
19
24
0
51
M322: 300-1000°C
H311: FSC <1500°C
H322: FSC <1200°C
Spot size diameter M [mm]
2
2.5
3
3.7
4.5
5.2
6
7.7
11.5
15.4
19.2
23
Fiber Ø 0.4 mm
M311/ M322: all
other temp. ranges
H311: FSC ≥1500°C
H322: FSC ≥1200°C
Spot size diameter M [mm]
FSC = Full scale temperature
M311/ M322: all
other temp. ranges
H311: FSC ≥1500°C
H322: FSC ≥1200°C
1
1.5
2
2.5
3
3.5
4
5
7.5
10
12.5
15
Fiber Ø 0.2 mm
0.8
1.3
1.5
1.8
2.3
2.8
4.6
5.8
7.3
7.8
2.8
5.8
7.8
11
14