METIS M311 / M322 / H311 / H322 (12-pin device connector)
7.2
Graphical Measurement Representation
Graphs tab:
Displays temperature
curves graphically.
Scaling scale:
with a mouse
click (upper
and lower scale
range)
by entering
Hold down
mouse and
drag to shift be-
ginning and
ending or the
entire area.
adjusts
the measure-
ment tempera-
ture scale to the
pyrometer
temp. range
(+10°C above
the maximum
value and -
10°C below the
minimum
value).
auto-
matically ad-
justs the meas-
urement tem-
perature scale
when the cur-
rent reading
runs out of the
display window.
INFO
to temporarily stored data: As soon as a device is connected in SensorTools, measurement data is
continuously saved (buffered). The amount of data is defined under
Data Recording Settings
▪ for an error-free display of the graph. If the amount of data is set too high for the computer's performance,
buffer overflows occur, which are shown as continuous vertical lines.
T-Sample (sampling time): Time
between the last two received
measured values.
T-Slope (slope time): Time be-
tween a start and an end tempera-
ture (tab "Time measurement")
T-Contr. (only devices with PID
controller): Time how long a con-
trol process has lasted
File name according to according to
Measuring-tem-
perature graphs
Measuring-tem-
perature scale
Start
Time in which the window is
empty
filled with measured values.
Viewer
Changing the time rebuilds the
graph from the center of the
window.
manually rebuilds the
graph from the left.
"Copy data file" allows you to quickly copy one or
more files to another folder. Select the file(s) and then
the target directory. If there are several files, the file
names can be automatically preceded by a designa-
tion. This function opens the data storage path di-
rectly, which can be changed in the
Options" tab, if necessary.
and can be adjusted there:
Model and serial number of con-
nected device(s):
Data Recording
Data Recording Settings
Start the
temporarily stored data
Start control process (only
devices with
Specify control parameters
File options
Select graph
or deselect.
Change color dis-
play: right-click for
color selection
Opens a
control win-
dow
for
each con-
nected de-
vice.
for all connected devices
simultaneously start / stop
/ pause / replay after
pause
"Communication /
"Maximum data sets in
Viewer
and transfer
PID
Controller)
Time /
Stopwatch:
sets the dis-
played time at the
current graph posi-
tion to 0
Recording
memory" in the
51
/ 81
Need help?
Do you have a question about the PROCESS SENSORS METIS M311 and is the answer not in the manual?
Questions and answers