Protective And Monitoring Equipment; Scope Of Delivery - WAGNER EvoMotion 20-30 Original Operating Manual

Piston pump
Hide thumbs Also See for EvoMotion 20-30:
Table of Contents

Advertisement

Operating manual Piston Pump EvoMotion 20-30
5   Description
5.3   PROTECTIVE AND MONITORING EQUIPMENT
Safety valve
WARNING
Overpressure!
Danger to life from bursting device components.
4 Never change the safety valve setting.
The air motor is fitted with a safety valve. The safety valve (10) has been set and sealed at the
factory. In case of pressures over and above the permissible operating pressure, the spring-
loaded valve, automatically opens and releases the excess pressure. As well as handling
pressure limits, the valve is also used as a pressure relief valve for the air motor.
10
Process for manually relieving pressure
1. Close ball valve (2).
2. Pull the ring on the safety valve (10) and hold it until the pressure in the air motor has
been equalized.
5.4   SCOPE OF DELIVERY
Piston pump consisting of:
-
Fluid section
-
Air motor
-
Connection set for air motor - fluid section
-
Air pressure regulator for air motor
The standard equipment includes:
Stk
Order no.
1
9992504
1
2333552
1
See Chapter
1
See Chapter Languages [8 6]
The delivery note shows the exact scope of delivery. Accessories: see Chapter Accessories
[8 50].
Order number 2333553 | Edition 09/2020
B_06894
Designation
Separating agent 250 ml
Operating manual, in German
Declaration of Conformity
Operating manual in the local lan-
guage
2
19