Operating manual Piston Pump EvoMotion 20-30
8   Cleaning and Maintenance
5. Carry out pressure relief in accordance with Chapter Pressure Relief / Work Interruption
[8 34].
6. Dispose of the contents of the tank (5) according to the local regulations.
8.2.7   Filling the Empty Pump
WARNING
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from flying parts.
Ignition of potentially explosive surrounding atmosphere.
4 Empty and fill the device slowly and in a controlled manner.
4 Avoid potentially explosive atmosphere in the surroundings.
Before each filling, the nozzle must be removed from the spray gun. Here, the specifications
in the spray gun operating manual must be followed. In case of AirCoat systems, carry out
the filling of the system without atomizing air (8).
A
1
2
B
3
7
4
6
System example EvoMotion 20-30 for the AirCoat procedure.
A
closed
1. Carry out a visual inspection: Personal protective equipment, grounding and all devices
ready for use.
2. Place an empty, grounded collection tank (5) under the return tube (4).
3. Place suction hose (7) in the tank with working material (6).
4. Close the pressure regulator (1) (0 MPa; 0 bar; 0 psi)
5. Open return valve (3).
Order number 2333553 | Edition 09/2020
9
8
5
B_06887
B
open