WAGNER EvoMotion 20-30 Original Operating Manual page 40

Piston pump
Hide thumbs Also See for EvoMotion 20-30:
Table of Contents

Advertisement

Operating manual Piston Pump EvoMotion 20-30
8   Cleaning and Maintenance
5. If the pump has to be emptied for maintenance work, proceed according to Chapter
Emptying Pump [8 41].
Weekly
1. Check system for damage.
2. Check that the safety fixtures function properly (see Chapter Protective and Monitoring
Equipment [8 19]).
Yearly or as required
1. In accordance with DGUV regulation 100-500, Chapters 2.29 and 2.36:
4 Have the liquid ejection devices checked by an expert (e.g. WAGNER service
technician) as required, but no later than every 12 months to ensure that they are in
safe working order.
4 For shut down devices, the examination can be suspended until the next start-up.
8.2.4   Filling with Separating Agent
NOTICE
Piston pump dry run
High wear/damage to the packings.
Paint or solvent can escape if the seals are dry.
4 Ensure that the separating agent tank is filled with sufficient separating agent.
B_06891
Pour the supplied separating agent into the separating agent cup.
Filling level: 1 cm; 0.4 inch under the cup edge.
Separating agent: order no. 9992504
Inclination angle of the pump
Maximum permissible inclination of pump for moving, transportation etc. after filling with
separating agent is ± 30°. The pump must be vertical during operation.
8.2.5   Product Hoses, Pipes and Couplings
The service life of the complete hoses between product pressure generator and application
device is reduced due to environmental influences even when handled correctly.
1. Check hoses, pipes, and couplings every day and replace if necessary.
2. Before every commissioning, check all connections for leaks.
3. Additionally, the operator must regularly check the complete hoses for wear and tear as
well as for damage at intervals that he/she has set. Records of these checks must be
kept.