Operating manual Piston Pump EvoMotion 20-30
7   Operation
WARNING
Incompatibility of cleaning/flushing agent and working medium!
Risk of explosion and danger of poisoning by toxic gases.
4 Examine the compatibility of the flushing and cleaning agents and working media
on the basis of the safety data sheets.
A
2
B
7
3
4
6
B_06888
A
closed
Preparation
1. Visual check: personal safety equipment, grounding and all devices ready to use.
2. Place an empty, grounded collection tank (5) under the return tube (4).
3. Place the suction hose (7) in the grounded tank with flushing agent (6).
4. Adjust the pressure regulator (1) to approx. 0.05 MPa; 0.5 bar; 7.25 psi.
Flushing via the return valve
1. Open return valve (3).
2. Slowly open the ball valve (2).
3. Adjust the air pressure on the pressure regulator (1) so that the pump runs smoothly.
4. Flush the system until clean flushing agent flows into the tank (5).
5. Close ball valve (2).
6. As soon as there is no pressure remaining in the system, close the return valve (3).
Flushing via the gun
1. In case of AirCoat systems, carry out the basic flushing without atomizing air.
36
8
1
9
5
B
open
Order number 2333553 | Edition 09/2020