Sid Window V Position; Time Code Window Enable; Time Code Window H Position - evertz 7700 Manual

Source identification decoder
Hide thumbs Also See for 7700:
Table of Contents

Advertisement

5.7.4. SID Window V Position

WINDOWS
SID WINDOW
V
0 to 19
4

5.7.5. Time Code Window Enable

WINDOWS
TIME CODE
WINDOW
ENABLE,
DISABLE

5.7.6. Time Code Window H Position

WINDOWS
TC WINDOW H
0 to 39
10
Starting row for the SID window.
This is the row of the SID display window counted from the top of the
screen.
When you select this parameter, the screen text will disappear and a box
of the correct size will appear. Move it around to the desired position with
the toggle switch. Press the push button when done.
On/ off control of the time code window.
The time code window can be turned off/on using this control.
Starting column for the time code window.
This is the character position of the first character in the time code
display window counted from the left side of the screen.
When you select this parameter, the screen text will disappear and a box
of the correct size will appear. Move it around to the desired position with
the toggle switch. Press the push button when done.
Warning, if you position the window near the audio bar graphs, you will
loose some text if you are in "TEXT" only mode (see "SDI Output" and
"Composite Output" above).
Revision 0.3
7700SID(-AM) Source Identification Decoder
7700 MultiFrame Manual
7700SID(-AM)-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

7700sid7700sid-am

Table of Contents