6.9.7. Configuring the VBI Processing
Composite Output
VBI Processing
Blank,
Pass
6.9.8. Selecting the Y Filter
Composite Output
Y Filter Selection
Wide bandwidth,
Composite
6.9.9.
Setting the Wideband Frequency
Composite Output
Wideband
Frequency
-6 to 6
0
6.9.10. Setting the Chroma Filter Bandwidth
Composite Output
Chroma Filter
650kHz,
1.0Mhz,
1.3MHz,
2.0MHz,
3.0MHz
The Vertical Blanking Interval may be passed to the component outputs or may
be blanked (removed) to not interfere with display of the image.
The Y channel may be filtered with a standard composite filter or may be
wideband. When Wide bandwidth is selected, the following control allows the
frequency response to be adjusted.
When the above parameter is set to Wide bandwidth, this controls a set of high
frequency response curves with +/- 4dB range.
Note: If you want to observe the filtering, supply a component multi-burst or H
sweep test signal.
The Cb and Cr channels may be filtered with any of these bandwidths.
Note: If you want to observe the filtering, supply a component multi-burst or H
sweep test signal.
Revision 1.1
7700 MultiFrame Manual
7714HDC High Quality Down Converter
7714HDC - 33