OPERATION
Model 8950-SID Digital Source ID Decoder Manual
SHIFT+SETUP
SHIFT+SELECT
SHIFT+# & SHIFT+ $ Fine adjustment of character vertical raster position
SHIFT+! & SHIFT+ "

3.1.5. An Overview of the Status Indicators

There are 6 status indicators located on the front panel that show
operational status of the 8950-SID at a glance.
4:2:2
Indicates that 8950-SID is configured for component digital
signals
BYPASS Indicates that 8950-SID is operating in the Bypass Mode. The
SDI video input is directly connected to the SDI Bypass output
and the 8950-SID will have no effect on the video signal.
COMM
Indicates that the 8950-SID is communicating with an external
computer device
VIDEO
Indicates that serial digital video is present. If it is blinking, it
indicates a valid digital video signal is not present
VITC IN
Indicates that VITC is being read
SID IN
Indicates that Source ID data is being read
Revision 1.0
Enters the Engineering Setup menu system
Resets the 8950-SID to factory defaults when you
are in the FACTORY RESET menu item of the
Engineering Setup Menu
Fine adjustment of character horizontal raster
position