Remove the midwall bracket
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
1.
Power down the server.
2.
If installed, open the cable management arm.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Remove the server from the rack.
6.
Place the server on a flat, level work surface.
7.
Remove the access panel.
8.
Do one of the following:
Remove the air baffle.
Remove the midplane drive cage.
9.
Remove the fan cage.
10. Remove the midwall bracket screws.
LFF chassis
Operations 55