3.7.7. Viewing the Firmware Version

FIRMWARE VERSION
1.1 build 66

3.7.8. Upgrading the Firmware

FIRMWARE UPGRADE
Upgrade
No
Yes

3.7.9. Resetting the HD9010TM-IRIG to its Factory Defaults

FACTORY RESET
Reset
No
Yes
3.8.

CONFIGURING THE GENERAL PURPOSE INPUTS AND OUTPUTS

A 9 pin D connector located on the rear panel labelled PARALLEL I/O provides control inputs for
remote control of some of the model HD9010TM-IRIG functions. Several of these inputs can also be
configured as open collector outputs that can be assigned to a variety of functions. The pinout of the D
connector when the HD9010TM-IRIG is not in the time rctl mode is shown in Error! Reference source
not found..
The GPI front panel display (accessible by pressing the DISPLAY button one or more times) will show
the status of the GPI inputs. The GPI status display (GPI: 11111111 ) is a group of 8 digits
representing the GPI inputs (GPI 8 on the left, GPI 1 on the right) When the digit is showing a 0, the
GPI input is low. When the digit is showing a 1 the input is high.
There are eight GPI inputs on Rev 2 units and three GPI inputs on Rev 1 units. Section 3.8.2 describes
the operation of the GPI functions when the HD9010TM-IRIG is not operating the time rctl mode
When the HD9010TM-IRIG is operating in the time rctl mode, the functions of these PARALLEL I/O
port GPI: 11111111pins are reassigned to provide a method of inputting Remote Control contact
OPERATION
HD9010TM-IRIG HDTV Time Code Master / IRIG-B Reader Manual
The Firmware Version menu item allows you to view the firmware
version that is installed in the HD9010TM-IRIG. When you press the
SELECT key, the display shows the software version which will be
something like:
1.1 build 66
The Firmware Upgrade menu item allows you to initiate an upgrade of
the firmware from the front panel. When you press the SELECT key,
you are prompted to confirm that you really want to upgrade. Turn the
shaft encoder knob to yes and then press the SELECT key to confirm.
When you press the SELECT key the unit will be placed in
programming mode and its serial port is opened to communicate with
the terminal software program.
UPGRADING... See section 4.1.10 for complete instructions on

upgrading the firmware.

The Factory Reset menu item allows you to reset the HD9010TM-IRIG
to its factory default condition. When you press the SELECT key, you
are prompted to confirm that you really want to reset the unit. Turn the
shaft encoder knob to yes and then press the SELECT key to confirm.
When you press the SELECT key the unit will be reset to its factory
default condition. The front panel display shows RESETTING....
Revision 2.1
The front panel display shows
Page 3-20