Power Connections; Mounting; Power Requirements; Table 2-3: Com2 Pin Definitions - evertz HD9010TM-IRIG Instruction Manual

Hdtv time code master with irig-b reader
Table of Contents

Advertisement

Pin
#
1
2
3
4
5
6
7
8
9

2.1.7. Power Connections

LINE:
The HD9010TM-IRIG Film Footage Encoder has a universal power supply operating on either
115v/60 Hz or 230v/50 Hz AC operation.
2.2.

MOUNTING

The HD9010TM-IRIG is equipped with rack mounting angles and fits into a standard 19 inches by 1.75
inches by 17.75 inches (483 mm x 45 mm x 451mm) rack space. The mounting angles may be removed if
rack mounting is not desired.
2.3.

POWER REQUIREMENTS

Power requirements are 115 or 230 volts AC at 50 or 60 Hz. The HD9010TM-IRIG has a universal power
supply that automatically senses the input voltage. Power should be applied by connecting a 3-wire
grounding type power supply cord to the power entry module on the rear panel. The power cord should be
minimum 18 AWG wire size; type SVT marked VW-1, maximum 2.5 m in length.
The power entry module combines a standard power inlet connector, two 5 x 20 mm fuse holders and an
EMI line filter.
CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK, GROUNDING OF THE
GROUND PIN OF THE MAINS PLUG MUST BE MAINTAINED
INSTALLATION
HD9010TM-IRIG HDTV Time Code Master / IRIG-B Reader Manual
Name
GND
Chassis ground
TxD
RS-232 Transmit Output
RxD
RS-232 Receive Input
Sig Gnd
RS-232 Signal Ground
RTS
RS-232 RTS Input
CTS
RS-232 CTS Output

Table 2-3: COM2 Pin Definitions

Description
Revision 2.1
Page 2-3