4.1.6. IRIG Reader
Standard:
IRIG 200-95 Formats B002 and B122
Connector:
3 pin female XLR type connector
Level:
0.2 to 4V p-p, balanced or unbalanced
4.1.7. Serial Ports
Standard: RS-232
Number: 2 ports
Baud Rate:
COM1 :
57600 baud (115,200 for Rev 2 hardware) for firmware upgrades
Programmable for IRIG CS-6 data broadcast applications
AUX COM : Programmable
Connectors: 9 pin female "D"
Control:
COM1 :
firmware upgrades, IRIG CS-6 data broadcast
AUX COM : Ingest of metadata for embedding into VANC
4.1.8. Physical
Dimensions: 19" W x 1.75" H x 18.75" D.
(483mm W x 45mm H x 477mm D)
Weight:
8 lbs. (3.5Kg)
4.1.9. Electrical
Power:
Auto ranging, 100
Safety:
ETL listed.
Complies with EU safety directive
EMI/RFI: Complies with FCC Part 15 Class A,
EU EMC Directive
4.1.10. Environmental
Temperature: 0 to 50 degrees C operating.
Humidity: 5 to 95 percent, non-condensing
4.2.
UPGRADING THE FIRMWARE
4.2.1. Overview
The firmware in the HD9010TM-IRIG is contained on a FLASH EPROM. From time to time firmware
updates will be provided to add additional features to the unit.
TECHNICAL DESCRIPTION
HD9010TM-IRIG HDTV Time Code Master / IRIG-B Reader Manual
240 VAC, 50/60 Hz 30 VA.
Revision 2.1
Page 4-2