Since the instrument is now generating two sets of outputs (one for each of the
reference signals) there are more output display choices in this mode than in single
reference mode, and these are listed in table 5-2. The outputs corresponding to the
two references are identified by the suffices "1" and "2" respectively.
Output
Description
Title
Numeric Displays only:
R
%
Resultant (Magnitude) output, reference 1, %FS
1
R
%
Resultant (Magnitude) output, reference 2, %FS
2
N
%
Noise output about reference 1, % FS
1
N
%
Noise output about reference 2, % FS
2
°
Phase output, reference 1, in degrees
1
°
Phase output, reference 2, in degrees
2
X
%
X channel output, reference 1, % FS
1
X
%
X channel output, reference 2, % FS
2
Y
%
Y channel output, reference 1, % FS
1
Y
%
Y channel output, reference 2, % FS
2
R
Resultant (Magnitude) output, reference 1, in volts or amps
1
R
Resultant (Magnitude) output, reference 2, in volts or amps
2
Numeric and Bar-Graph Displays:
X
X channel output, reference 1, in volts or amps
1
X
X channel output, reference 2, in volts or amps
2
Y
Y channel output, reference 1, in volts or amps
1
Y
Y channel output, reference 2, in volts or amps
2
N
Noise output about reference 1 in volts or amps per root hertz
1
N
Noise output about reference 1 in volts or amps per root hertz
1
ADC1
ADC1 input, ±10.000 V full-scale
ADC2
ADC2 input, ±10.000 V full-scale
ADC3
ADC3 input, ±10.000 V full-scale
ADC4
ADC4 input, ±10.000 V full-scale
Bar-Graph Displays only:
MAG
Resultant (Magnitude) output, reference 1, in volts or amps
1
MAG
Resultant (Magnitude) output, reference 2, in volts or amps
2
PHA
°
Phase output, reference 1, in degrees
1
PHA
°
Phase output, reference 2, in degrees
2
Table 5-2, Output Display Choices - Dual Reference Mode
The additional outputs may be stored to the curve buffer.
When in dual reference mode, the user-defined equations, specified on the Output
Equations menu (see section 5.3.08), allow the selection of the additional outputs as
variables. For example, it is possible to calculate a value proportional to the ratio of
the X
channel output to that of the X
1
be output to one of the DAC connectors on the rear panel of the main console as an
analog voltage.
Note: Unless both the 7124 Main Console AUX input and one of the 7124 RCU's