Hioki RM3545A-1 Startup Manual page 9

Resistance meter
Hide thumbs Also See for RM3545A-1:

Advertisement

Product warranty
3 years
duration
Fuse
F1.6AH 250 V (installed inside the main body,
replaceable)
Measurement items Resistance, temperature
Measurement range
Resistance
1
2
Ω
LP*
PR*
100 M
range
High-
precision
000.000 μ
to 1200.0 M
10 M
OFF
= 1,000,000 digits
100 M
OFF
scale = 10,000 digits
000.000 μ
ON
120.000 0 M
Full scale = 1,000,000 digits
0.00 m
ON
OFF
1200.00
Full scale = 100,000 digits
*1. Low-power mode
*2. Pure resistance mode
°
Temperature
−10.0
C to 99.9
Measurement
Constant current
signal
Measurement
DC four-terminal method
method
Measurement
1 A, 100 mA, 10 mA, 1 mA, 500 µA, 100 µA,
current
50 µA, 10 µA, 5 µA, 1 µA, 1 µA or less, 100 nA
Depends on the measurement ranges.
For more information, see resistance
measurement accuracy table in "Measurement
accuracy" in the Instruction Manual.
EXT. I/O
Connector
Female 37-pin D-sub, with #4-40 Screw lock
Input
Input type
Input asserted
(ON)
Input asserted
(OFF)
Response time ON edge: Max. 0.1 ms
Output
Output type
Maximum load
voltage
Residual
voltage
Maximum
output current
Measuring range and
Number
full scale
ranges
Ω
Ω
(1000 μ
range)
Ω
Ω
(1000 M
range)
Ω
range or less: full scale
Ω
range or greater: full
Ω
Ω
(1000 μ
range) to
Ω
Ω
(100 M
range)
Ω
Ω
(1000 m
range) to
Ω
Ω
(1000
range)
°
C
Photocoupler-isolated no-
voltage contact input
(current sink/source output
compatible)
Residual voltage: 1 V or
less (Input ON current: 4 mA
(reference value))
Open (shutoff current: 100 μA or
less)
OFF edge: Max. 1.0 ms
Photocoupler-isolated open-
drain output (non-polar)
DC 30 V
1 V or less (load current:
50 mA)
0.5 V or less (load current:
10 mA)
50 mA/channel
HIOKI RM3545E965-00
Service power
supply output
of
For other specifications, see "12 Specifications" in the
Instruction Manual.
Function Specifications
13
(1) Resistance range switching
See: Instruction Manual "12.3 Function Specifications
(1) Resistance range switching"
Ω
(2) 100 M
range high-precision mode
12
See: Instruction Manual "4.14 Increasing the Precision
of the 100 M
precision Mode)"
4
(3) Number of measurement digits selection
See: Instruction Manual "4.7 Changing the Number of
Measured Value Digits"
(4) Pure resistance mode (PR)
See: Instruction Manual "4.9 Switching to Pure
Resistance Mode (PR)"
(5) Low-power mode (LP)
See: Instruction Manual "4.1 Switching to Low-power
Mode (LP)"
(6) Switching Measurement Currents
See: Instruction Manual "4.2 Switching Measurement
Currents (100 m
(7) Measurement speed setting
See: Instruction Manual "3.3 Setting the Measurement
Speed"
(8) Set the power frequency
See: Instruction Manual "6.3 Power Line Frequency
Manual Setting"
(9) Zero adjustment
See: Instruction Manual "4.3 Performing Zero
Adjustment"
(10) Averaging
See: Instruction Manual "4.4 Stabilizing Measured
Values (Averaging Function)"
(11) Delay setting
See: Instruction Manual "4.10 Setting Pre-Measurement
Delay (Delay Function)"
(12) Temperature measurement settings
See: Instruction Manual "12.3 Function Specifications
(12) Temperature measurement settings"
(13) Temperature correction function (TC)
See: Instruction Manual "4.5 Correcting for the Effects
of Temperature (Temperature Correction [TC])"
(14) Offset voltage compensation
See: Instruction Manual "4.8 Compensating for Thermal
EMF Offset (OVC Function)"
9
Output voltage For sink output: 5.0 V
For source output:
±
−5.0 V
10%, 100 mA max.
Isolation
Floating from protective ground
potential and measurement
circuit
Insulation
Line to ground voltage 50 V DC,
rating
or 30 V AC rms and 42.4 V AC
peak or less
Ω
Ω
Range (100 M
Range High-
Ω
Ω
to 100
range)"
±
10%