Part Names And Functions - Hioki RM3545A-1 Startup Manual

Resistance meter
Hide thumbs Also See for RM3545A-1:

Advertisement

Part Names and Functions

Example: The RM3545A-2 is shown.
1
1
2
2
14
14
15
15
1
1
Measurement
terminals
2 2
Display screen
3 3
COMP indicator
LEDs
4 4
COMP
key
5 5
Cursor key
6 6
PANEL
key
7 7
AUTO
key
8 8
RANGE
key
9 9
SPEED
key
10
10
STANDBY key
11
11
ENTER
key
12
12
ESC
key
13
13
F
keys
14
14
MENU
key
15
15
COMP.OUT terminal
*1. Programmable controller
3 4 4
3
5 5
6 6
7
7
13
13
12
12
11
11
10
10
Connect the measurement leads.
Monochrome graphical LCD.
Indicate the judgment result of the
measured value when using the
comparator function.
Sets the comparator function.
Moves among items shown on the
screen.
Saves or loads the settings.
(Panel Save function, Panel Load
function)
Switches between the auto range and
the manual range.
Switches the measurement range
when the manual range is selected.
Switches the measurement speed.
Unlit: Power off (when no power
supplied)
Red light: Standby state (while power
is supplied)
Green light: Power on
Confirms the settings displayed on
the screen.
Cancels the settings displayed on the
screen.
Selection of settings displayed on the
screen.
Displays the Settings screen or
switches the pages.
Connect the L2105 LED Comparator
Attachment.
16
16
29
29
8
8
9
9
28
28
16
16
Power inlet
17
17
EXT. I/O connector
18
18
LAN connector
19
19
USB connector
20
20
Fuse holder
21
21
MAC address
22
22
Manufacturing
number
23
23
EXT. I/O MODE NPN/
PNP switch
24
24
TEMP.SENSOR
terminal
25
25
TEMP.ANALOG
INPUT terminal
26
26
D/A OUTPUT
terminal
27
27
RS-232C connector
28
28
Main power switch
29
29
Multiplexer unit slot
(RM3545A-2 only)
HIOKI RM3545E965-00
7
17
17
18
18
22
22
27
27
26
26
25
25
23
23
24
24
Connect the included power cord.
Allows external control of the
instrument.
Allows control of the instrument with
a PC or PLC*
1
.
Allows control of the instrument with
1
a PC or PLC*
.
For replacement of the fuse.
MAC address of LAN
Production control number
Allows you to change the type of
1
PLC*
to be connected with the
EXT. I/O connector.
Left: Current sink (NPN)
Right: Current source (PNP)
Connect the Z2001 Temperature
Sensor.
Connect an analog output
thermometer.
Outputs a voltage level that
correspond to the resistance value.
(Connect a device that can accept
voltage input, for example, a
Memory HiCorder.)
Allows control of the instrument with
1
a PC or PLC*
.
Switches On/Off the main power
supply of the instrument.
Install the Z3003 Multiplexer Unit.
(Max. 2)
19
19
21
21
20
20

Advertisement

loading

This manual is also suitable for:

Rm3545a-2