Determining (User) Gain Values - Beckhoff EL3681 Documentation

Digital multimeter terminal
Table of Contents

Advertisement

Commissioning
5.6.5

Determining (user) gain values

The terminal has one user compensation value pair for each measuring range and measurement type, i.e.
14 pairs in total. "+1" (0x4000) is not used in order to increase the resolution of the gain value.
Since the gain values may be less than 1, an offset of 1/8 is added to the gain value. For a gain of 1 the gain
value must be 0x2000. For gain G = 1 the following applies:
For other values G must be replaced with the required gain factor.
Before the compensation the value display option should be set to "Right-aligned": CoE index 0x8000:1D
[} 155] (presentation = 1).
EL3681
Version: 3.0
153