8.5.3

Configuring the lock

1. Configuring the default lock
Please follow the steps below:
[1] On the "Outdoor Stations" screen, go to the "Lock management" section.
[2] Select the lock type from the drop-down list.
It can be set to "Lock-GND", "NO-NC-COM" or "IP Actuator".
If the lock type is set to "IP Actuator", you need to select the lock type from the drop-down
list. It can be set to "Power lock" or "Relay lock".
[3] Enter the unlock time.
If lock type = "Lock-GND" or "Power lock", you need to set the time for the power lock.
If lock type = "NO-NC-COM" or "Relay lock", you need to set the time for the signal lock.
Product manual 2TMD042300D0041
Commissioning
│141