8.5

Configuring the Outdoor Station

8.5.1

Accessing the "Outoodr Stations" screen

This chapter applies to the mini Outdoor Station and pushbutton Outdoor Station.
Entering engineering mode
Please follow the steps below:
[1] Power on the Outdoor Station, wait until all 3 LED indicators go out.
[2] Press and hold the first pushbutton for the designated time until all 3 LED indicators flash.
For the mini Outdoor Station, the designated time = 5 seconds
For the pushbutton Outdoor Station, the designated time = 10 seconds
Accessing the "Outdoor Stations" screen
The following operations use the pushbutton Outdoor Station as an example.
Please follow the steps below:
[1] Ensure that the Outdoor Station is in engineering mode.
[2] On the "Settings" screen of the panel, tap "Advanced settings".
[3] Tap "Outdoor Stations" to access the corresponding screen.
Note
The Outdoor Station will exit engineering mode if no operation is carried out for 5
minutes.
Product manual 2TMD042300D0041
Commissioning
│134