Tab le of c ont e nts Notes on the instruction manual ......................4 Safety ..............................4 Intended use ............................5 Environment ............................6 Busch-Jaeger devices ........................ 6 Product description ..........................7 Device type ..........................7 Control elements........................8 Terminal description ........................9 Lock type and connection ......................
Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. Busch-Jaeger accepts no liability for any failure to observe the instructions in this manual.
Intended use Intended use As part of the ABB-Welcome IP system, this device can only be used with accessories from that system. Security mode This outdoor station runs in "Security mode" by default to guarantee high security. In "Security mode", this outdoor station requires a certificate issued by the management software before it can function normally.
Busch-Jaeger devices All packaging materials and devices from Busch-Jaeger bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
Product description Product description Device type Size (HxWxD) Article Product ID Product name Colour number Unit: mm H81381T-S- Stainless 2TMA130010X0027 IP touch 5" outdoor station 135 x 349 x 29 steel H81381T- 2TMA130010W0017 IP touch 5" outdoor station White 135 x 349 x 29 W-03 Product manual 2TMD041800D0008 │7...
Product description Control elements Function Camera Speaker and microphone integration 5-inch touch display End strip Product manual 2TMD041800D0008 │8...
Product description Terminal description Function Reset button Micro USB update connector Plug-in clamps (DC+...GND) for standalone power supply Plug-in clamps (LOCK...GND) for door opener Plug-in clamps (COM...NC...NO) for floating output, door opener LAN (PoE) Connector for next module Connector for exit button Connector for the sensor used for door status detection Connector for 5"...
Product description Lock type and connection Lock type Operation type Voltage Wiring type Electrical strike ⎓ Power on to open Type A/B 12 V lock, 12V Electrical strike ⎓ Power on to open Type B 24 V lock, 24V Electrical rim Power on to open ⎓...
Technical data Technical data Designation Value Rating voltage ⎓ 24 V Operating voltage range ⎓ 20-27 V ⎓ 27 V , 410 mA Rating current ⎓ 24 V , 450 mA Operating temperature -20 °C…+55 °C Camera type CMOS Camera viewing angle 130°...
Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
Mounting/Installation Mounting 7.2.1 Preparation Use gloves to protect yourself against cuts. 7.2.2 Installation height 1.5 m 5 feet Product manual 2TMD041800D0008 │13...
Page 14
Mounting/Installation Note The following installation situations must be avoided without fail to ensure picture quality: Direct light ■ Direct sunlight ■ Extremely bright picture background ■ Highly reflective walls on the opposite side of the door station ■ Product manual 2TMD041800D0008 │14...
Commissioning Commissioning Welcome screen and home screen This outdoor station will light up and display the welcome screen when someone approaches the station or if the station screen is touched. Click the bulletin to display it as full screen. Click the area (not the bulletin) to access the home screen (see the picture below on the right). Function Welcome message If there is no bulletin, the Welcome screen will display according to the welcome screen time.
Commissioning Entering the "Settings" screen On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. Note The engineering password must be changed the first time you access the engineering settings. (The system default is 345678. This password should only be used for initial setting work and should be changed to another password.
Commissioning Access control settings On "Settings" screen, tap "Access control" to access the corresponding screen. Level 1 Level 2 Level 3 Option ■ Private password Off (default) ■ Password On, 3...8 digits ■ Public password Off (default) ■ On (default) ■...
Commissioning System settings On the "Settings" screen, tap "System settings" to access the corresponding screen. Level 1 Level 2 Level 3 Option Volume 1...5 Ringback volume 1...3 Ringtone ■ settings Voice prompts Off (default) ■ On (default) ■ Ringtone feedback ■...
Page 25
Commissioning Level 1 Level 2 Level 3 Option Lock-GND NO-NC-COM Default lock Power lock (ID range: ■ 1...32) IP actuator Relay lock (ID range: ■ 1...32) Lock-GND NO-NC-COM Subsidiary lock Power lock (ID range: ■ 1...32) IP actuator Relay lock (ID range: ■...
Page 26
Commissioning Level 1 Level 2 Level 3 Option Major version ■ MCU version ■ Version Hardware version ■ Display version ■ (This number is used to obtain the certificate issued by the Serial number System settings Help management software.) Displays the value if the Signature certificate issued is obtained successfully.
Operation Operation Call a resident via keypad 1. Call a resident via the room number Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings" screen, complete the following settings: "Engineering settings">>"System attribute">>"Default call type">>"Call via keypad"...
Page 28
Operation 2. Call a resident via the specified code Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings" screen, complete the following settings: "Engineering settings">>"System attribute">>"Default call type">>"Call via keypad" ■...
Page 29
Operation Initiating a call using the specific code On the home screen, enter the specific code (e.g. A1), followed by " " to initiate a call. Product manual 2TMD041800D0008 │29...
Operation Call a resident via the address book Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings" screen, complete the following settings: "Engineering settings">>"System attribute">>"Default call type">>"Call from address book" ■...
Page 31
Operation Initiating a call from the address book On the home screen, tap a contact from the address book to access a countdown screen. Tap "Stop call" to pause the call. ■ Tap the countdown number or call button to continue the call. ■...
Operation Call guard unit Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings" screen, complete the following settings: "Engineering settings">>"System attribute">>"Call guard unit">>"On">> enter the guard unit ■...
Operation Releasing the lock by entering a password 9.4.1 Releasing the lock with a password set on the indoor station Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■ password] [#] to access the "Settings" screen. On the "Settings"...
Page 34
Operation Releasing the lock by entering the password On the home screen of the outdoor station, tap " ", enter [*] [address] [#] [password] ■ [#], followed by " " to release the lock. – If call mode = physical and device type = outdoor station, [address] = room number –...
Operation 9.4.2 Releasing the lock with a password set on the local outdoor station Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■ password] [#] to access the "Settings" screen. On the "Settings" screen, complete the following settings: "Access control">>"Password">>"Public password">>"On">>enter a 3~8 digits password.
Operation 9.4.3 Releasing the lock with a password set on the App Precondition You need to create an unlock password on the Welcome App. For more information, please see the Welcome App manual. Releasing the lock by entering a password On the "...
Operation 9.4.4 Releasing the lock with a password set in the management software Precondition You need to create an unlock password in the management software. For more details, please see the management software manual. Releasing the lock by entering a password On the "...
Operation Releasing the lock with a QR code set on the App You need to pair the Welcome App with an indoor station before this function is used. 1. Create an unlock QR code Please see the Welcome App product manual for more details. Product manual 2TMD041800D0008 │38...
Page 39
Operation 2. Use the unlock QR code on the outdoor station On the outdoor station, [1] On the home screen, tap " ", followed by enter [#] [*] [engineering password] [#] to access the "Settings" screen. [2] On the "Settings" screen, tap "System settings", " Unlock type configuration ", " QR code unlock ", "On"...
Operation Releasing the lock by swiping IC cards Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■ password] [#] to access the "Settings" screen. On the "Settings" screen, complete the following settings: "Access control">>"Card mode">>"Safe mode">>"On"...
Page 41
Operation Releasing the lock by swiping an IC card Swipe a registered IC card on the specified area to release the lock. IC card specification Operating frequency 13.56 MHz Standard ISO 14443A Support card Mifare one S50/S70, Mifare desfire EV1/EV2 Output format Wiegand 26/34 bit Product manual 2TMD041800D0008...
H8138.T-. product, the network, its system and interfaces against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. Busch-Jaeger and its affiliates are not liable for damages and/or losses related to such security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information.
Malware prevention solution The H8138.T-. device is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is via firmware upgrades. Only firmware signed by Busch-Jaeger can be accepted. 10.7 Password rule The user must change the engineering password when accessing the engineering settings for the first time.
We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. Busch-Jaeger accepts no responsibility for possible errors or incompleteness in this document.