Busch-Jaeger Busch-Welcome H8138.T 03 Series Product Manual

Busch-Jaeger Busch-Welcome H8138.T 03 Series Product Manual

Ip touch 5" outdoor station

Advertisement

Quick Links

2TMD041800D0008 │ 27.10.2022
Product manual
®
Busch-Welcome
IP
H8138.T-.-03 IP touch 5" outdoor station

Advertisement

Table of Contents
loading

Summary of Contents for Busch-Jaeger Busch-Welcome H8138.T 03 Series

  • Page 1 2TMD041800D0008 │ 27.10.2022 Product manual ® Busch-Welcome H8138.T-.-03 IP touch 5" outdoor station...
  • Page 2: Table Of Contents

    Tab le of c ont e nts Notes on the instruction manual ......................4 Safety ..............................4 Intended use ............................5 Environment ............................6 Busch-Jaeger devices ........................ 6 Product description ..........................7 Device type ..........................7 Control elements........................8 Terminal description ........................9 Lock type and connection ......................
  • Page 3 Table of contents 10.2 Performance and service ......................42 10.3 Deployment guideline....................... 43 10.4 Upgrading..........................43 10.5 Backup/Restore ........................43 10.6 Malware prevention solution ..................... 43 10.7 Password rule .......................... 43 Notice ..............................44 Product manual 2TMD041800D0008 │3...
  • Page 4: Notes On The Instruction Manual

    Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. Busch-Jaeger accepts no liability for any failure to observe the instructions in this manual.
  • Page 5: Intended Use

    Intended use Intended use As part of the ABB-Welcome IP system, this device can only be used with accessories from that system. Security mode This outdoor station runs in "Security mode" by default to guarantee high security. In "Security mode", this outdoor station requires a certificate issued by the management software before it can function normally.
  • Page 6: Environment

    Busch-Jaeger devices All packaging materials and devices from Busch-Jaeger bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
  • Page 7: Product Description

    Product description Product description Device type Size (HxWxD) Article Product ID Product name Colour number Unit: mm H81381T-S- Stainless 2TMA130010X0027 IP touch 5" outdoor station 135 x 349 x 29 steel H81381T- 2TMA130010W0017 IP touch 5" outdoor station White 135 x 349 x 29 W-03 Product manual 2TMD041800D0008 │7...
  • Page 8: Control Elements

    Product description Control elements Function Camera Speaker and microphone integration 5-inch touch display End strip Product manual 2TMD041800D0008 │8...
  • Page 9: Terminal Description

    Product description Terminal description Function Reset button Micro USB update connector Plug-in clamps (DC+...GND) for standalone power supply Plug-in clamps (LOCK...GND) for door opener Plug-in clamps (COM...NC...NO) for floating output, door opener LAN (PoE) Connector for next module Connector for exit button Connector for the sensor used for door status detection Connector for 5"...
  • Page 10: Lock Type And Connection

    Product description Lock type and connection Lock type Operation type Voltage Wiring type Electrical strike ⎓ Power on to open Type A/B 12 V lock, 12V Electrical strike ⎓ Power on to open Type B 24 V lock, 24V Electrical rim Power on to open ⎓...
  • Page 11: Technical Data

    Technical data Technical data Designation Value Rating voltage ⎓ 24 V Operating voltage range ⎓ 20-27 V ⎓ 27 V , 410 mA Rating current ⎓ 24 V , 450 mA Operating temperature -20 °C…+55 °C Camera type CMOS Camera viewing angle 130°...
  • Page 12: Mounting/Installation

    Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
  • Page 13: Mounting

    Mounting/Installation Mounting 7.2.1 Preparation Use gloves to protect yourself against cuts. 7.2.2 Installation height 1.5 m 5 feet Product manual 2TMD041800D0008 │13...
  • Page 14 Mounting/Installation Note The following installation situations must be avoided without fail to ensure picture quality: Direct light ■ Direct sunlight ■ Extremely bright picture background ■ Highly reflective walls on the opposite side of the door station ■ Product manual 2TMD041800D0008 │14...
  • Page 15: Surface-Mounted Installation

    Mounting/Installation 7.2.3 Surface-mounted installation 40 mm 71 mm Product manual 2TMD041800D0008 │15...
  • Page 16: Flush-Mounted Installation

    Mounting/Installation 7.2.4 Flush-mounted installation 1. Flush-mounted without pre-installation box 46 mm 117 mm Product manual 2TMD041800D0008 │16...
  • Page 17 Mounting/Installation 2. Flush-mounted with pre-installation box 126 m m 68 m m Product manual 2TMD041800D0008 │17...
  • Page 18: Cavity Wall Installation

    Mounting/Installation 7.2.5 Cavity wall installation Product manual 2TMD041800D0008 │18...
  • Page 19: Dismantling

    Mounting/Installation 7.2.6 Dismantling Product manual 2TMD041800D0008 │19...
  • Page 20: Commissioning

    Commissioning Commissioning Welcome screen and home screen This outdoor station will light up and display the welcome screen when someone approaches the station or if the station screen is touched. Click the bulletin to display it as full screen. Click the area (not the bulletin) to access the home screen (see the picture below on the right). Function Welcome message If there is no bulletin, the Welcome screen will display according to the welcome screen time.
  • Page 21: Entering The "Settings" Screen

    Commissioning Entering the "Settings" screen On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. Note The engineering password must be changed the first time you access the engineering settings. (The system default is 345678. This password should only be used for initial setting work and should be changed to another password.
  • Page 22: Engineering Settings

    Commissioning Engineering settings On the "Settings" screen, tap "Engineering settings" to access the corresponding screen. Level 1 Level 2 Level 3 Option Block no. Outdoor station: 001...999 Outdoor station ■ Device type Device attribute Gate station ■ Outdoor station: 01...64 ■...
  • Page 23: Access Control Settings

    Commissioning Access control settings On "Settings" screen, tap "Access control" to access the corresponding screen. Level 1 Level 2 Level 3 Option ■ Private password Off (default) ■ Password On, 3...8 digits ■ Public password Off (default) ■ On (default) ■...
  • Page 24: System Settings

    Commissioning System settings On the "Settings" screen, tap "System settings" to access the corresponding screen. Level 1 Level 2 Level 3 Option Volume 1...5 Ringback volume 1...3 Ringtone ■ settings Voice prompts Off (default) ■ On (default) ■ Ringtone feedback ■...
  • Page 25 Commissioning Level 1 Level 2 Level 3 Option Lock-GND NO-NC-COM Default lock Power lock (ID range: ■ 1...32) IP actuator Relay lock (ID range: ■ 1...32) Lock-GND NO-NC-COM Subsidiary lock Power lock (ID range: ■ 1...32) IP actuator Relay lock (ID range: ■...
  • Page 26 Commissioning Level 1 Level 2 Level 3 Option Major version ■ MCU version ■ Version Hardware version ■ Display version ■ (This number is used to obtain the certificate issued by the Serial number System settings Help management software.) Displays the value if the Signature certificate issued is obtained successfully.
  • Page 27: Operation

    Operation Operation Call a resident via keypad 1. Call a resident via the room number Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings" screen, complete the following settings: "Engineering settings">>"System attribute">>"Default call type">>"Call via keypad"...
  • Page 28 Operation 2. Call a resident via the specified code Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings" screen, complete the following settings: "Engineering settings">>"System attribute">>"Default call type">>"Call via keypad" ■...
  • Page 29 Operation Initiating a call using the specific code On the home screen, enter the specific code (e.g. A1), followed by " " to initiate a call. Product manual 2TMD041800D0008 │29...
  • Page 30: Call A Resident Via The Address Book

    Operation Call a resident via the address book Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings" screen, complete the following settings: "Engineering settings">>"System attribute">>"Default call type">>"Call from address book" ■...
  • Page 31 Operation Initiating a call from the address book On the home screen, tap a contact from the address book to access a countdown screen. Tap "Stop call" to pause the call. ■ Tap the countdown number or call button to continue the call. ■...
  • Page 32: Call Guard Unit

    Operation Call guard unit Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings" screen, complete the following settings: "Engineering settings">>"System attribute">>"Call guard unit">>"On">> enter the guard unit ■...
  • Page 33: Releasing The Lock By Entering A Password

    Operation Releasing the lock by entering a password 9.4.1 Releasing the lock with a password set on the indoor station Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■ password] [#] to access the "Settings" screen. On the "Settings"...
  • Page 34 Operation Releasing the lock by entering the password On the home screen of the outdoor station, tap " ", enter [*] [address] [#] [password] ■ [#], followed by " " to release the lock. – If call mode = physical and device type = outdoor station, [address] = room number –...
  • Page 35: Releasing The Lock With A Password Set On The Local Outdoor Station

    Operation 9.4.2 Releasing the lock with a password set on the local outdoor station Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■ password] [#] to access the "Settings" screen. On the "Settings" screen, complete the following settings: "Access control">>"Password">>"Public password">>"On">>enter a 3~8 digits password.
  • Page 36: Releasing The Lock With A Password Set On The App

    Operation 9.4.3 Releasing the lock with a password set on the App Precondition You need to create an unlock password on the Welcome App. For more information, please see the Welcome App manual. Releasing the lock by entering a password On the "...
  • Page 37: Releasing The Lock With A Password Set In The Management Software

    Operation 9.4.4 Releasing the lock with a password set in the management software Precondition You need to create an unlock password in the management software. For more details, please see the management software manual. Releasing the lock by entering a password On the "...
  • Page 38: Releasing The Lock With A Qr Code Set On The App

    Operation Releasing the lock with a QR code set on the App You need to pair the Welcome App with an indoor station before this function is used. 1. Create an unlock QR code Please see the Welcome App product manual for more details. Product manual 2TMD041800D0008 │38...
  • Page 39 Operation 2. Use the unlock QR code on the outdoor station On the outdoor station, [1] On the home screen, tap " ", followed by enter [#] [*] [engineering password] [#] to access the "Settings" screen. [2] On the "Settings" screen, tap "System settings", " Unlock type configuration ", " QR code unlock ", "On"...
  • Page 40: Releasing The Lock By Swiping Ic Cards

    Operation Releasing the lock by swiping IC cards Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■ password] [#] to access the "Settings" screen. On the "Settings" screen, complete the following settings: "Access control">>"Card mode">>"Safe mode">>"On"...
  • Page 41 Operation Releasing the lock by swiping an IC card Swipe a registered IC card on the specified area to release the lock. IC card specification Operating frequency 13.56 MHz Standard ISO 14443A Support card Mifare one S50/S70, Mifare desfire EV1/EV2 Output format Wiegand 26/34 bit Product manual 2TMD041800D0008...
  • Page 42: Cyber Security

    H8138.T-. product, the network, its system and interfaces against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. Busch-Jaeger and its affiliates are not liable for damages and/or losses related to such security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information.
  • Page 43: Deployment Guideline

    Malware prevention solution The H8138.T-. device is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is via firmware upgrades. Only firmware signed by Busch-Jaeger can be accepted. 10.7 Password rule The user must change the engineering password when accessing the engineering settings for the first time.
  • Page 44: Notice

    We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. Busch-Jaeger accepts no responsibility for possible errors or incompleteness in this document.
  • Page 45 Busch-Jaeger Elektro GmbH A member of the ABB Group Freisenbergstraße 2 58513 Lüdenscheid www.BUSCH-JAEGER.de info.bje@de.abb.com Central sales service: Tel.: +49 2351 956-1600 Fax: +49 2351 956-1700 Copyright © 2021 Busch-Jaeger Elektro GmbH All rights reserved...

This manual is also suitable for:

Busch-welcome h81381t-s03Busch-welcome h81381tw-03Busch-welcome ip h8138 t 03 seriesBusch-welcome ip h81381t-s03Busch-welcome ip h81381tw-03