16 SCAN
16.3 Transceiver Behavior during the Scan
Configuration
The channel configured for Priority Zone-Channel (Analog) or Priority Zone-Channel (NXDN) is used as the
Fixed
Priority Channel. For Mobile, "P" appears for 1 sec.
Selected
The selected channel is used as the Priority Channel.
The channel selected by a user is used as the Priority Channel.
Operator Selectable
By pressing the Priority Zone-Channel Select key while the transceiver is in normal mode, a Tone A sounds
from the transceiver and the selected channel becomes the Priority Channel. For Mobile, "P" appears for 1 sec.
Note
• The transceiver does not monitor the Priority Channel by using Lookback while the transceiver pauses the scan on the Priority
Channel. (Refer to
Lookback on page
• For Mobile, the transceiver can be configured to light the 2 dots on the LED display (the left dot and the right dot) and the LED (blue)
when Priority Zone-Channel is enabled. (Refer to
Configuration using KPG-169D/ KPG-170D/ KPG-175D
Configuring the Priority (
Configuring the Priority Zone-Channel (Analog) (
Configuring the Priority Zone-Channel (NXDN) (
Assigning functions to the PF keys (
16.3
Transceiver Behavior during the Scan
Note
The amount of time from when the transceiver pauses scanning for transmission or reception until the transceiver resumes scanning
can be configured using Dropout Delay Time and Transmit Dwell Time. (Refer to
Time on page
177.)
Conditions to Resume the Scan
One of the following conditions must be met to resume scanning while the transceiver pauses scanning. If no condition is
satisfied, the scan continues pausing.
Two or more channels to be scanned must coexist in the selected zone.
One channel to be scanned must exist in the selected zone and the Priority Channel must exist in the zone or
another zone. However, the configuration for Zone Type (Analog or NXDN) of the zone where the Priority Channel
exists must be the same as the configuration of the zone where the transceiver starts the scan.
Note
For Mobile, if Off-hook Scan is disabled, the scan is resumed when the microphone status is switched from the off-hook to the on-hook.
However, the scan cannot be resumed under the condition that neither of the above requirements is satisfied. (Refer to
Scanning by Linking with the Microphone (Off-hook Scan) on page
FUNC (K)/Ver 1.20
Table 16-1 Priority Scan
177.)
5.5 Lighting the LEDs According to the Transceiver's Status on page
Edit > Scan Information > Scan)
See
See
See
Edit > Key Assignment)
See
Description
Edit > Scan Information > Scan)
Edit > Scan Information > Scan)
Dropout Delay Time on page
178.)
CONTENTS
25.)
177,
Transmit Dwell
Starting
INDEX
173

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-240vNx-340Nx-340uNx-740hNx-740hvNx-840h ... Show all

Table of Contents