KEB COMBIVERT F5 Instruction Manual page 34

Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Display Plaintext COMBIVIS
A. OL
ABN.STOP overload
A.OL2
ABN.STOP overload 2
GB
A.PrF
ABN.STOP prot. rot. for.
A.Prr
ABN.STOP prot. rot. rev.
GB
A.SbuS ABN.Bus synchron
A.SEt
ABN.STOP set
A.SLF
ABN.Software limit switch forward
A.SLr
ABN.Software limit switch reverse
GB- 34
Value Meaning
99
A level between 0 and 100 % of the load counter can be
adjusted, when it is exceeded this warning is output. The
response to this warning can be programmed (see chapter
6.7 "Response to errors or warning messages").
100
The warning is output when the standstill continuous current
is exceeded (see technical data and overload
characteristics). The response to this warning can be
programmed (see chapter 6.7 "Response to errors and
warning messages"). The warning message can only be
reset after the cooling time has elapsed and A.nOL2 is
displayed.
94
The drive is driven onto the right limit switch. The response
to this warning can be programmed (see chapter 6.7
"Response to errors and warning messages").
95
The drive is driven onto the left limit switch. The response to
this warning can be programmed (see chapter 6.7
"Response to errors and warning messages").
103
Synchronization over sercos-bus not possible. The response
to this warning can be programmed (see chapter 6.7
"Response to errors and warning messages").
102
Warning: set selection: It has been attempted to select a
locked parameter set. The response to this warning can be
programmed (see chapter 6.7 "Response to errors or
warning messages").
104
The right software limit switch lies outside the defined limits.
The response to this warning can be programmed (see
chapter 6.7 "Response to errors or warning messages").
105
The left software limit switch lies outside the defined limits.
The response to this warning can be programmed (see
chapter 6.7 "Response to errors or warning messages").